Joinwit JW3209 Series Manual

Optical multimeter

Advertisement

NOTICE
All trademarks and names mentioned in this
manual belong to Shanghai Joinwit.
Shanghai Joinwit has the right of the manual
interpretation.
Trademarks
All trademarks mentioned in this manual are
registered property of Joinwit.
Explanation
The content of this manual is subject to Joinwit's
explanation.
www.joinwit.com

Advertisement

Table of Contents
loading

Summary of Contents for Joinwit JW3209 Series

  • Page 1 All trademarks and names mentioned in this manual belong to Shanghai Joinwit. Shanghai Joinwit has the right of the manual interpretation. Trademarks All trademarks mentioned in this manual are registered property of Joinwit. Explanation The content of this manual is subject to Joinwit’s explanation.
  • Page 2: Table Of Contents

    Contents overview ----------------------------------------------------------1 Technical Specifications ----------------------------------------2 iii. Technical Specifications ----------------------------------------3 Instrument Introduction --------------------------------------4-5 Instructions for Use -----------------------------------------5-19 Troubleshooting ------------------------------------------------19 vii. Care and Maintenance -------------------------------------19-20 viii. Quality Assurance ---------------------------------------------20 -----------------------------------21 Attachment 1 Product Warranty Card ----------------------------------------22 Attachment 2 Warranty Conditions...
  • Page 3: Overview

    、Overview JW3209 is the company highly cost-effective optical multimeter. It’s the integration of power meter and light source. JW3209 has the function of recording, storing and uploading the data tested by the instrument. They are widely used in the fiber-optic line project construction, testing and maintenance, such as digital data network, telecommunication network and cable television.
  • Page 4: Technical Specifications

    ① 、Technical Specifications Instrument model JW3209A JW3209C parameters Power meter Calibration 850、1300、 1310、1490、1550、1625 wavelength(nm) Testing range(dBm) -70~+6 -50~+26 Display resolution(dB) 0.01 Uncertainty(dB) ≤±0.25 linearity(dB) ≤±0.1 Frequency indentification <10K range Source Working wavelenght(nm) 1310/1550(customizable) Typical Output Power(dBm) -5(customizable) Stability(dB,30min,20℃) ≤0.1dB Modulation frequency (Hz) CW,270Hz,1KHz,2KHz...
  • Page 5: Technical Specifications

    、Standard Configaration JW3209 instrument-------------------------------------------------------------------1pc instructions------------------------------------------------------------------------------1copy Data disc---------------------------------------------------------------------------------1pc Mini USB data cable-------------------------------------------------------------------1pc 5V USB adapter-------------------------------------------------------------------------1pc 1.5V Alkaline Battery-----------------------------------------------------------------------3pcs Cleaning Swabs---------------------------------------------------------------------------1pack Soft Oxford cloth pack ------------------------------------------------------------------1pc certificate-----------------------------------------------------------------------------------1pc 、Instrument Introduction (13) (12)
  • Page 6 (11) (10) 图 4-1 Function Introduction ① :Turn on or off the meter ② :Switching wavelength under test ③ :Turn on or off the backlight ④ :data testing storage\Viewing; automatic switching of source wavelength ⑤ :delete the current data record ⑥...
  • Page 7: Instructions For Use

    ⑩ Meter display window Mini USB interface: ⑪ data communication interface;adapter power supply interface ⑫ Laser source output port ⑬ Power meter testing input port 、Instructions for Use When powered by dry battery, the bottom left corner of the instrument screen will display Auto-off sign after turning on ;if no other operations within 10mins, the...
  • Page 8 1. Power meter mode :Sequentially switching to the meter internal tested wavelength :change among dBm、dB、XW in turn (image5-4) dBm unit dB unit xW unit Image 5-4 : ① Short press button,start REF function. When the current tested value is set or changed to reference value, the instrument comes to relative power measurement, and the top right corner of the screen will show“Ref”...
  • Page 9 When the meter needs “System Zero”, the dust cap of the power meter detecting port must be tightened to ensure no light input. And then long press this button for about 5 seconds to have the automatic “System Zero” and the previous screen.
  • Page 10 Image 5-8 button: Delete data:in the data view status,press button to delete the current record. 2. Source mode button:Sequentially switching to the meter internal source wavelength. button:turn on or off the laser output in the source .(image 5-9) Image 5-9 button:After turning on the laser in the source module, press the button...
  • Page 11 图 5-11 Short press button,the meter top right corner displays”--AU”to indicate this function is started. Meanwhile, the laser output wavelength in the source module will be switched automatically according to the change of the same wavelength in the power meter module.
  • Page 12 -20dBm. 6.Power meter calibration mode In the power meter mode,press“ ”and“ ”, at the same time, “U-01”will appear on the screen top right corner, indicating that the meter has come to power value calibration mode.
  • Page 13 7.1 Install driver Running the CD-ROM on the computer to find the “driver”installation file,image 5-16。 Image 5-16 Double-click the icon,image 5-17 appears Image 5-17 click“INSTALL” ,After a moment,image 5-18 appears. Image 5-18 Click “OK” and exit the installation interface. Driver installation has not been completed at this time, please continue the operation below.
  • Page 14 Image 5-19 Click Next to appear image 5-20。 Image 5-20 After a moment,image 5-21 appears. Image 5-21 Click Finish, driver installation is completed. Please check that if the driver is installed to avoid the communication problem between the instrument and the computer Open device manager (right-click My Computer to select properties.
  • Page 15 Image 5-22 Image 5-23 After the successful driver installation, you can turn off the instrument and disconnect the USB. Instruction for the Software Use (1)Open the PC software to show the image 5-24.
  • Page 16 Image 5-24 The instrument is connected to the computer by a USB cable and in the state of being switched on. In the port(COM and LPT) column, you can see the port used by the instrument is “COM4”(image 5-25)
  • Page 17 Image 5-26 After port selection, click the “Open Com“button, and then click “Connect” button.(image 5-27) When the successful connection box appears, click OK to finish connection. And now you can start the communication between the instrument and computer。(image5-28) Image 5-27...
  • Page 18 Image 5-30 You can process the data in the data display area, including delete, save and print. Choose the data needing process; click the “Delete Select” button to delete the selected data, as in the image 5-31 and 5-32,and also the corresponding data stored in the meter are also deleted.
  • Page 19 Image 5-33 Click the “Save or Print” button to appear the sheet in the image 5-34. The sheet can be edited, saved, printed and etc. Click button to appear save box in the image 5-35. You can operate the file name, save path, etc.
  • Page 20 5-35 (3) Power reading and calibration Click the “Power Read” button, the current absolute optical power value, tested in the instrument power meter module, will appear in the empty box; Click the “Wave Selection” drop-down box to select the current test wavelength in the instrument power meter module;...
  • Page 21: Troubleshooting

    Image 5-38 (5)Close Software Click the “Exit”button is OK. 、Troubleshooting Fault Situations Possible Cause Solutions Weak or no LCD display after ① Low battery ① change battery the instrument turning on ① The internal source connection ① Using the special cotton...
  • Page 22: Quality Assurance

    (2)The instrument is improperly or negligently used or due to the accident, etc. Warranty Registration Card For every Joinwit product, it has a warranty registration card. Please send it to the company together with the purchase invoice copy after filling in so that we can have a root record of your instrument after the future maintenance, technological innovation, calibration and so on.
  • Page 23: Attachment1 Product Warranty Card

    Attachment1 Product Warranty Card Joinwit Optoelectronic Tech, Co., Ltd Product warranty card Product model: Product serial number: purchase date: User name: Tel: Fax: Address: Zip code: E——mail: Stamp: (Please keep this part.Cut down the below part and send is to us) ………………...
  • Page 24: Attachment2 Warranty Conditions

    Attachment2 Warranty Conditions Joinwit Optoelectronic Tech, Co., Ltd Warranty conditions warranty: Within 18 months after buying date Warranty terms: In the warranty period, if the product failure occurs under normal use, the user can produce this warranty card and invoice or receipt (copy) to enjoy free repair service.

This manual is also suitable for:

Jw3209aJw3209c

Table of Contents