Print Delay; Electrical Connection - Nuovo EB Easy-Printer Operating Manual

Table of Contents

Advertisement

Nuovo

6.3 Print delay

To synchronize the machine with the packing lane, adjust the delay-time using the selector switch [6].
6

6.4 Electrical connection

The EASY-PRINT has to be internally connected as follows:
Eggland's Best, Inc. Operating Standards Manual- EB Easy Printer Manual 16/001
Confidential. Do not reproduce without permission
Operating instructions for use
EB EASY-PRINTER
6
Selector switch for setting
the delay-time of the
stamper
For the start signal, there are two possibilities:
Give start with a potential free contact.
Direct, already connected
Connect the blue connector with wire colour yellow and
orange to position number 1 (x0) on the Easy unit
Connect the start signal + positive (white wire) to colour
yellow on the connection strip
Connect the start signal - negative (yellow wire) to colour
orange on the connection strip
Give start signal with direct current (max 24 V)
(Optocoupler)
Connect the blue connector (optocoupler) with wire colour
black and green to position number 1 (x0) on the Easy unit
Connect the start signal + positive (brown wire) to colour
blue on the connection strip
Connect the start signal - negative (green wire) to colour
red on the connection strip
(as shown on scheme)
6