Glossary; Safety Devices - Matco Tools AC442 Operation Manual

R134a touchscreen automatic rrr. a/c service equipment
Hide thumbs Also See for AC442:
Table of Contents

Advertisement

8 | AC442 |
en
 
2.5

Safety devices

Description
Function
Pressure
Switches the compressor off in the normal operating
switch
pressure is exceeded
Safety valve The safety valve opens if the design pressure is
exceeded
Circuit
Interrupts the power supply if overcurrent is applied to
Breaker
the AC442
Vents
The AC442 is provided with vents in the housing to
ensure the exchange of air even when switched off.
2.6
Proper disposal
At the end of its service life, this equipment must
be disposed of as follows:
Contact the service center to have the refrigerant
in the unit recovered and recycled.
Consign the unit to an authorized collection
center according to local legislation.
2.7
Recycled material disposal
Return the refrigerant recovered from
the unit to the refrigerant supplier for
proper disposal or recycling.
Lubricants extracted from the vehicle's
A/C system must be returned to an
official oil collection center
2.8
Packaging disposal
Electronic and electrical A/C service
equipment must never be disposed of with
domestic waste, but recycled
appropriately.
The packaging must be disposed of in
conformity with local legislation.
This contributes to protecting the
environment
2.9
Disposal of combo filter
Dispose of the filter via official
collection points or in accordance with
the local regulations. This contributes
to protecting the environment
 
1901016-85
2.10
Technical Data
Description
R134a tank capacity
Service pressure
Maximum content
Method to weigh gas content
Recovered oil container
Vacuum pump
Vacuum pump oil quantity
Compressor capacity
Dryer filter
Non-condensable gas purge
HP and LP taps
Display
Software updating
Printer (optional)
All functions
Recycling mode
Memory for customized
cycles
Flushing
System pressure diagnostics
Dryer filter replacement alarm
Vacuum pump oil
replacement alarm
Full/empty tank check alarm
Full oil container check alarm
Empty oil container alarm
Dimension H x W x D
Dry weight
Power supply frequency
Voltage
Total max load
Overcurrent protection
Operating temperature
Humidity
Storage temperature and
humidity
Max operating altitude
Pollution degree
Water degree
Certifications
2.11

Glossary

Recovery phase: The refrigerant is extracted from the
vehicle air conditioning system, cleaned and routed into the
internal bottle of the AC442. The refrigerant oil collected in
the process is drained into the used oil bottle at the AC442.
Vacuum phase: A vacuum is generated in the vehicle air
conditioning system. Measurement of the drop in pressure
begins as soon as the vacuum has been generated.
Charging phase: A certain quantity of refrigerant is added
to the vehicle air conditioning system.
Specification
12L
400PSI
22lbs.
Load cell
250ml
2CFM dual stage
250ml
0.87cu in/14cc
90kg recovered R134a
Automatic via solenoid valve
Automatic
7 inch capacitive touch screen
USB type A or USB type B direct
connect to PC
Thermal, 24 columns
Automatic and manual
Single pass
100 records
With integrated solenoid valves
Manual and automatic
Active
Active
Active
Visual
Visual
119 x 74 x 74 cm
98kg
60Hz
120VAC, 1 phase
7.5A
12A (circuit breaker)
50 - 122°F
10 90%RH (non-condensing)
-13 to 50°F
10 - 90%RH (non-condensing)
6562 ft.
2
0
SAE J2788
UL 1963