C System Service; Automatic Cycle Setup; Manual Cycle Setup - Matco Tools AC442 Operation Manual

R134a touchscreen automatic rrr. a/c service equipment
Hide thumbs Also See for AC442:
Table of Contents

Advertisement

en
19| AC442 | A/C System service
 
9 A/C system service
9.1

Automatic cycle setup

Access to automatic cycles is available through the
main menu by selecting AUTOMATIC.
Do not connect hoses/couplers to vehicle A/C system
until prompted by the unit.
All values in the AUTOMATIC cycle mode are preset
and unable to be modified from the Automatic menu,
except for the refrigerant charge amount. If changing
the value of the vacuum amount is desired, select a
MANUAL process and choose all 3 services to be
performed.
1. From the main menu, select AUTOMATIC.
2. Adjust the charge value to match that of the vehicle
manufacturer's recommended value.
Fig. 14: Adjusting charge value
3. To change which hose the unit will charge, touch the
blue box at the bottom of the screen that says LP-HP. A
menu will pop up that allows technician to select which
hoses/couplers to charge through.
4. If the technician wishes to perform a pressure check of
the A/C system, they should select Vehicle Pressure
check at the bottom of the screen. (When highlighted
BLUE, the pressure check function is selected; when in
GREY, the unit will not perform a pressure check.)
5. After options are properly adjusted, press the green
arrow in the lower right corner of the screen.
Fig. 15: Automatic setting confirmation
6. If settings are correct, press START button to begin
process
 
9.2

Manual cycle setup

Access to manual cycles is available through the main menu
by selecting MANUAL CYCLES.
Do not connect hoses/couplers to vehicle A/C system until
prompted by the unit.
1.
From the main menu, select MANUAL.
Fig. 16: Manual setting selection
2.
Select the services desired by touching button at the
upper right corner of each column. (Figure shows charge
service selected)
See the sections about Recovery, Vacuum, and Charge on
the next page for more detailed cycle setting information.
3.
To change the charge hose, touch the blue box at the
bottom of the screen that says LP-HP. A menu will pop
up that allows technician to select which hoses/couplers
to charge through.
4.
If the technician wishes to perform a pressure check of
the A/C system, they should select Pressure check at the
bottom of the screen. (When highlighted BLUE, the
pressure check function is selected; when in GREY, the
unit will not perform a pressure check.)
5.
After options are properly adjusted, press the green
arrow in the lower right corner of the screen.
6.
The unit will display a screen to confirm process
settings. Press the START button to begin process.
7.
Follow on-screen instructions to complete cycle.
1901016-85

Advertisement

Table of Contents
loading

Table of Contents