CCH YPV6 Series Operation Manual

Mobile air conditioner

Advertisement

YPV6 Series Mobile Air Conditioner
Operation Manual
• •
YPV6-12C&YPV6-14C
Thank you for your choice of this high-quality mobile air c
r. Please read this manual
carefully before use. For problems if any, please contact professional servicemen.

Advertisement

Table of Contents
loading

Summary of Contents for CCH YPV6 Series

  • Page 1 YPV6 Series Mobile Air Conditioner Operation Manual • • YPV6-12C&YPV6-14C Thank you for your choice of this high-quality mobile air c r. Please read this manual carefully before use. For problems if any, please contact professional servicemen.
  • Page 2: Table Of Contents

    Table of Contents User Instructions Precautions............................1 Important Safety Tips..........................3 Special Remarks...........................6 Product Introduction Components and Parts........................7 Control Panel and Remote Control......................8 Use of Product Storage and Installation........................9 Operating Method..........................12 Cleaning and Maintenance Drainage Method..........................13 Maintenance............................13 Common Failures and Diagnosis Intelligent Detection of Failures......................16 Failure Repair.............................16 Some Technical Parameters of Machine Fuse Parameters..........................16...
  • Page 3: User Instructions

    USER INSTRUCTIONS The meaning of icons used in this manual is as follows: For your and your families’ health and safety, please do not perform such operations. For your and your families’ health and safety, please do perform the following issues. Precautions This machine is only for household, please Please use this machine indoor and put it in...
  • Page 4 Please do not operate this machine with Please wipe this machine with soft cloth, wet hands or in humid environment. and waxes, diluents or irritant detergents are prohibited for use. Please clean strainer frequently, and once For your health, please do not drink per two weeks is recommended.
  • Page 5: Important Safety Tips

    Important safety tips Do not damage or use damaged and Please do not damaged power lines or type unknown power lines. Before use, plugs; please do not insert power line into please make sure the voltage applied is in loose socket. compliance with the requirements.
  • Page 6 Please shut down the machine before Do not control on/off status of the machine extracting plug. through insertion and extraction of power plug. Please do not share one power socket with Please keep this machine away from direct multiple large-power appliances. sunlight.
  • Page 7 Please do not insert fingers or hard objects Please do not allow water to enterelectric into air deflecting strip at the air part of this machine. If water enters inside of the machine, If wiping, cleaning and moving the please shut it down immediately and machine or replacement of machine disconnect plug, and then contact components is required, please shut...
  • Page 8: Special Remarks

    Special Remarks A space of at least 50cm should be Place the air conditions on flat ground, and maintained between the air conditioner keep vertical to guarantee normal and surrounding objects, and meanwhile air operation of compressor. inlet and outlet should be kept unimpeded. Do not use sprays or other solvents close to Please do not use this machine in the this machine, otherwise plastic deformation...
  • Page 9: Product Introduction

    PRODUCT INTRODUCTION Components and Parts 2. Control panel 3. Air outlet 4. Caster 5. Side plate 7. Air inlet 8. Remote control 10. Power cord 11. Drain cover Heat 12. Exhaust pipe assembly 13. Installation kit assembly...
  • Page 10: Control Panel And Remote Control

    Components and Parts Power on/off key Pressing this key can turn on/off the air conditioner. Mode selection Pressing this key can select refrigeration, air supply, dehumidification and auto modes. F Conversion key ° ° Pressing this key can realize display conversion between°C and°F.
  • Page 11: Use Of Product

    USE OF PRODUCT Storage - Place this machine on horizontal floor close to window; - In order to maintain perfect ventilation and achieve the best performance, a space of at least 50cm around the machine should be reserved; Installation Exhaust pipe assembly Installation kit assembly Screw Step 1:...
  • Page 12 9/10 Step 3: Screw exhaust pipe assembly (exhaust joint end) into the air outlet on rear panel (in anti-clockwise direction). Step 4: Small notch Click exhaust pipe assembly (exhaust flat nozzle end) into installation kit assembly and fix with screw. Screw Then slide and lock First insert...
  • Page 13: Remote Control

    Warning: The length of exhaust pipe is especially designed for this type and should not be replaced or extended without permission, otherwise failure may be caused. Attention: The max spread length of exhaust pipe is 1500mm, please reduce the length as much as possible during use, and remaining exhaust pipe level as much as possible during installation is recommended.
  • Page 14: Operating Method

    11/12 Operating method Refrigeration mode • After power-on startup take refrigeration mode as default or press mode key to select refrigeration mode, and refrigeration indicator lamp is on. • Pressing UP/DOWN key can regulate setting temperature (17°C~30°C). • Pressing air speed key can select high, medium or low air speed. Air supply mode •...
  • Page 15: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Drainage method This product is provided with automatic water evaporation system. Condensate circulation cools condenser. This not only improves refrigerating efficiency, but also saves energy. If water container inside the machine is full of water, the display screen will flash show “FL” with sound alarm, compressor stops operation automatically.
  • Page 16 13/14 Filters Cleaning of strainer once per two weeks is recommended, and the cleaning frequency should be properly increased if indoor air quality is bad. Jamming of strainer by dust will reduce efficacy of the air conditioner. The specific cleaning steps are as follows: 1.
  • Page 17: Seasonal Maintenance

    Seasonal maintenance If this machine is in idle for long time, please maintain it as per the following steps: 1. Extract water plug at the water outlet to drain water. 2. Keep the air conditioner running in air supply mode or 2h till the inside is blown dry.
  • Page 18: Common Failures And Diagnosis

    15/16 COMMON FAILURES AND DIAGNOSIS Intelligent Detection of Failures Detection codes Multifunction detection Failure of coil temperature sensor Failure of indoor temperature sensor Anti-freeze protection: when coil temperature is lower than 0 ℃ , shut down whole machine. As coil temperature rises again above 8 ℃ , the protection is relieved and the original operating state is resumed.