Falcon G3425 Installation And Servicing Instructions

Chargrill

Advertisement

Quick Links

G3425, G3625, G3925,
G31225 and G31525 Chargrills
G3625, G3925, G31225
and G31525 ES Chargrills
INSTALLATION and SERVICING
INSTRUCTIONS
The appliance must be installed and serviced by a qualified person as stipulated by the Gas
Safety (Installation & Use) Regulations.
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and
National Regulations in force at the time of installation. Particular attention MUST be paid to:
Gas Safety (Installation & Use) Regulations
Health And Safety At Work etc. Act
Local and National Building Regulations
Fire Precautions Act
The appliance has been CE-marked on the basis of compliance with the Gas Appliance Directive for the
Countries, Gas Types and Pressures as stated on the data plate.
WARNING
On completion of the installation, these instructions should be left with the Engineer-in-Charge for reference
during servicing. Further to this, The Users Instructions should be handed over to the User, having had a
demonstration of the operation and cleaning of the Appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND
COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES
MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a maintenance contract
be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out adjustments and
repairs. A quotation will be given upon request to the contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement
parts in a safe manner, via a licensed waste handler.
Units are designed to be dismantled easily and recycling
of all material is encouraged whenever practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000
TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC,
:
MUST BE EARTHED.
Fax: 01438 369 900
Detailed recommendations are contained in
Institute of Gas Engineers published documents:
IGE/UP1, IGE/UP/2
BS6173 and BS5440
T100766 Ref. 6

Advertisement

Table of Contents
loading

Summary of Contents for Falcon G3425

  • Page 1 G3425, G3625, G3925, G31225 and G31525 Chargrills G3625, G3925, G31225 and G31525 ES Chargrills INSTALLATION and SERVICING INSTRUCTIONS The appliance must be installed and serviced by a qualified person as stipulated by the Gas Safety (Installation & Use) Regulations. IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation.
  • Page 2 IMPORTANT INFORMATION Warranty Policy Shortlist Warranty does not cover :- • Correcting faults caused by incorrect installation of a product. • Where an engineer cannot gain access to a site or a product. • Repeat commission visits. • Replacement of any parts where damage has been caused by misuse. •...
  • Page 3: Section 1 - Installation

    The unit may be installed on a table, counter top or purpose designed floor stand, available from Falcon. The unit must be installed on a firm, level surface in a well lit, suitably ventilated position. Models may be installed to within 175mm of a combustible wall at the back and sides.
  • Page 4 1.5.1 Burner Injector Sizes - Natural Gas (in mm) Model/ No. of burners G3425 Chargrill Ø3.0 G3625 Chargrill Ø2.6 Ø2.6 G3925 Chargrill Ø2.6 Ø2.6 Ø2.6 G31225 Chargrill Ø2.6 Ø2.6 Ø2.4 Ø2.5 G31525 Chargrill Ø2.6 Ø2.4 Ø2.3 Ø2.4 Ø2.4 Model/ No. of burners G3625ES Chargrill Ø1.95...
  • Page 5: Section 2 - Assembly And Commissioning

    Flame cones shall be stable and display good burner cross-lighting on both LOW and HIGH settings. There should be no yellow tipping or flame lift. Burner aeration has been set by Falcon and should not be altered unless absolutely necessary.
  • Page 6: Instruction To User

    Advise User that unit and installation should be SERVICED and INSPECTED REGULARLY as recommended by Falcon. For continued safe and efficient operation, the user should be aware that any smell emitting from the new appliance will quickly disappear.
  • Page 7 INJECTORS To access, remove burners as detailed in Section 3.3.1. Undo injectors using a spanner. Soak in a suitable solvent to remove debris and wipe with a soft rag. DO NOT USE metal implements to clear an injector orifice. Check seals are clean before refitting and that this is carried out in the correct order.
  • Page 8: Spark Igniter

    GOVERNOR This applies to NATURAL GAS models ONLY. The type of governor supplied is maintenance free. Check that blue dust cap covering vent is fitted and in good condition as this protects the breather hole. When fitting governor, ensure that direction arrow points toward unit inlet. SPARK IGNITER To access connections, open control panel assembly as detailed in Section 3.2.

This manual is also suitable for:

G3625G3925G31225G31525G3925esG3625es ... Show all

Table of Contents