  • Page 2: Product Type

    Please read this manual carefully and store it so that you can use it later. Read the warning and safety notes attentive. Further information and latest software releases or documents can be downloaded from: www.senect.de © SENECT GmbH & Co. KG - FW 00.80...
  • Page 3: Table Of Contents

    Installation and start-up ........................6 Operation .............................. 14 Display and symbols .......................... 14 Buttons and menu ..........................15 Accessoires for the SENECT FILTER|CONTROL ..................33 Connecting a solenoid valve to refill water ..................33 Troubleshooting: What if… ........................33 Technical Data ............................34 Information about the correct disposal ....................
  • Page 4: Used Symbols And Wording

    Further information for the use of the device. General Security Notes The SENECT® FILTER|CONTROL is an electronic control unit developed for controlling drum and belt filters. Since it is an electric product the common prerequisites for a safe instrument usage must be fulfilled.
  • Page 5: Intended Use

    The SENECT® FILTER|CONTROL is an electronic control unit developed for controlling drum and belt filter in industrial applications. It can be combined with maximal two water level sensors (SENECT PS-300-MA or EPS-250-MA), one filter case switch, one solenoid valve (MVW-M12-SC) and one further actuator (e.g. alarm lamp VIS- LED).
  • Page 6: Getting Started

    Getting started filter mesh is clogged, the FILTER|CONTROL starts the filter motor so that the drum starts to rotate or the belt starts to move and the spray pump will be activated. The filter mesh will be flushed and all dirt particles will be washed to the outlet. Alternatively, if the is no water level sensor connected to the FILTER|CONTROL, a time controlled operation of the filter is also possible.
  • Page 7 Getting started Fig. 1: Connecting an open channel drum filter and a boxed drum filter. Please note that the filter motors here are controlled by the high-power acuator output port OUT 3.
  • Page 8 Getting started Fig. 1: Wall mounting parts and dimensions of the drill holes of the FILTER|CONTROL. Plug the 230 V power plug of the FILTER|CONTROL in a spray water protected plug (IPx4 or higher) but do not switch FILTER|CONTROL on yet. 1.) Water level sensor installation If you do not have a water level sensor, please continue with 2.).
  • Page 9 If your filter is equipped with a case or cover proximity switch, you can connect it to SENSOR 3. If you do not have a suitable plug at your switch, you can order the proper plug from SENECT or your dealer.
  • Page 10 FILTER|CONTROL and the filter motor is necessary. SENECT offers fully configurated, parametrized and wired VFDs. The green labelled actuator cable from the VFD must be connected to one the actuator output ports, e.g. OUT 1.
  • Page 11 Getting started 4.) Connecting the spray and circulation pump If the pumps are correctly installed, arrange all cables safely to your FILTER|CONTROL. Check on the data sheets of your pumps, if they fit to the specifications of the FILTER|CONTROL (spray pump: 230 V AC, max. 1800 W, circulation pump: 230 V AC, max. 900 W). Plug the spray pump connector into the plug „SPRAY PUMP“...
  • Page 12 Getting started STARTING THE SYSTEM Switch the FILTER|CONTROL on with the ON/OFF Switch at the bottom (Fig. 3). Note: Changing languages can be easiliy done in the menu. Press the button MENU and select under „System Einstellungen / Sprache“ the language „English“. By pressing the button MENU, you can configure all necessary settings.
  • Page 13 Getting started Connect the filter motor cable, the spray pump, the water level sensor, the cover switch and the circulation pump with your FILTER|CONTROL. a. If you are using a VFD, connect the motor to the VFD, connect the green marked actuator cable of the VFD to the FILTER|CONTROL to OUT 1 and plug the VFD power plug into a power supply mains plug.
  • Page 14: Operation

    Operation Operation Display and symbols On the display, you´ll find information about current measurement and the status of the instrument. The upper row shows you action symbols, which display the current running actions or modes of operation. The action symbols are: Fig.
  • Page 15: Buttons And Menu

    0. WATER: If there is a SENECT soleonoid valve connected, pressing WATER leads you directly to the water refill menu. If you press WATER longer than 3 s, the solenoid valve is opended until you release the button.
  • Page 16 Operation All settings and parameters can be set in the menu. The following overview shows the menu exemplarily. Please consider that some parts of the menu are dynamic, which means that they only appear in certain constellation or with certain equipment. Table 1: Description of the history entries.
  • Page 17 Operation Filter Settings Filter Mode Gravity System Pumped System Operating Mode Deactivate Automatic Mode Time-controlled High-Press. Cleaner Extras Deactivate Dynamic|Mode Eco|Mode Cover Sw. DF Cover Sw. EBF Dry run Prot. Off Dry run pro. pump sump. Water Level Flush Level Dry run Protection 1 Dry run Protection 2 (only pumped system) Backwash Parameter...
  • Page 18 Filter settings Filter settings Here you can configure all relevant settings for the filter operation.  Filter Mode Select here, if you are using your filter in a gravity or pumped system. The selection here means that the filters backwashing is triggered by an decrease of the water level (typically for gravity mode, where the sensor is installed behind the filter) or by an increase (when the sensor is installed before the filter).
  • Page 19 Filter settings  Extras Here you can select the activation of extra functions. 1. Dynamic|Mode: The Dynamic|Mode is a special algorithm which leads to a more stable clogging-induced control of the backwashing. With this mode, the backwash water level is continuously corrected for changes in the water level.
  • Page 20 Filter settings  Backwash Parameter Here you can set all relevant parameters for the filter cleaning.  Backwash Duration The backwash duration defines the time of one cleaning cycle. Choose the flush time so that the drum is rotated at least one time completely. ...
  • Page 21: Water Refill

     Service interval (here you can select to be alarmed regularly e.g. when the filter has been backwashed 10.000 times. This function is intended to be a reminder for any maintenance work) Water Refill If there is a SENECT solenoid valve connected to the FILTER|CONTROL, you can refill water on different ways.
  • Page 22 Water Refill  Mode The „automatic water refill mode” uses the measurements of the water level sensor in the tank, pond or pre-chamber. In the time-controlled mode, water is refilled based on your time settings in the timer table or by intervals. You can also combine different types of the refill mode.
  • Page 23 Sensors  Interval mode With the interval function, you can define time intervals on which the refilling should be activated. Enter here the duration of each refill event, e.g. always refill for 5 minutes and the interval between the events, e.g. every 2 hours. ...
  • Page 24 Menu output ports and 230 V AC plugs  Cover switch Not every filter is equipped with a cover switch. That´s why the cover switch can be deactivated in this menu item. Please consider here that a cover switch is used for enhancing the security. If your filter is not equipped with a cover switch, never open the cover when the FILTER|CONTROL is operating! Menu output ports and 230 V AC plugs...
  • Page 25 Menu output ports and 230 V AC plugs and the mode, how both should interact. You can choose between “Off”, “Off when on”, “Off when off”, “On when on” and “On when off”. Additionally to the normal function, the extra function “time-controlled” can be added. It works analogous to the time-controlled function of the water refill where you can either enter specific times or define intervals.
  • Page 26 Menu output ports and 230 V AC plugs  Circulation pump When defined as „circulation pump“, the output is switched on in normal mode, but will be switched off in case of alarming (e.g. water level below dry-run protection). Additionally, the circulation pump can be switched on and off with the STOP or PUMP button (break symbol in the display).
  • Page 27 Menu output ports and 230 V AC plugs When the function „Alarm“ is selected, the output responds to alarm detections and activeates the port. For example, the user can be warned visually by an alarm lamp (z.B. SENECT alarm lamp VIS-LED).
  • Page 28 Windows (Version 7 or higher), Android or iOS-based device on which the SENECT Control App is installed. The SENECT Control App is available in the Google Playstore or the Apple App Store. The Windows-version of the app can be downloaded on www.senect.de/app.
  • Page 29 Menu output ports and 230 V AC plugs Embedding the FILTER|CONTROL unit in your SENECT Control App: 1. Open the SENECT Control App and press the button “Add control unit” 2. Choose an individual name for the control unit and enter its IP Adress (you´ll find it under Menu/WLAN/Information).
  • Page 30 Menu output ports and 230 V AC plugs 3. Select at “Gerät” the FILTER|CONTROL. It will be labelled with “Senect-101xxxxx”, where the x denote the serial number of your FILTER|CONTROL. 4. Click on “Neue Freigabe” and the Anwendung is “Andere Anwendung”...
  • Page 31 5. Select as „Schema“: „http://“ and type in the port number of the FILTER|CONTROL (30000 as factory setting, if you use several SENECT control units, each single one must have its own port number. You can change it in the menu/WLAN/Port number) 6.
  • Page 32 DNS address of the control unit. You need this address in the SENECT Control App to establish the remote access. To enable the remote access with the SENECT Control App, you need to go to the WLAN settings of the control unit in your App. Press therefore the button “settings”.
  • Page 33: Accessoires For The Senect Filter|Control

    Accessoires for the SENECT FILTER|CONTROL  System Settings  Date & Time Set the date and time in this menu item. The FILTER|CONTROL is equipped with an internal rechargeable battery so that even without a power connection, the clock continues and all relevant settings are saved.
  • Page 34: Technical Data

    Technical Data … the measurement values of the water level probe fluctuate: In this case the water level probe is often placed in a location with high currents and measures the impact of the flow. Please relocate the probe to a place with only minor currents. …there are long-term changes in the values of the water level probe: Is the water level changing by 5 to 15 cm over days additionally to the short term changes induced by the filter clogging, then it is likely that the capillary cable of the probe is damaged...
  • Page 35: Guarantee

    Guarantee The SENECT GmbH & Co. KG is member of the Stiftung Elektro-Altgeräte Register and the products are registered (WEEE-Reg.-Nr.: DE37193510). Guarantee Please check at delivery of your FILTER|CONTROL, that all parts are delivered completely and that they function correctly. In case of any claims, contact us immediately per email or phone (info@senect.de...