  • Page 1 AUTOMATIC DOORS FOR LIFTS Assembly manual. Automatic horizontal sliding car door. Component: VF5 Electronic Module. MAN-MMCAENGV5TC-10.2017...
  • Page 2 CONNECTIONS AUTOMATIC DOORS FOR LIFTS ASYNC...
  • Page 3 PROGRAMMING AUTOMATIC DOORS FOR LIFTS The VF may be programmed using the DIP switches on the front of the unit. If any 2 3 4 change is made to any of the above switch selections, the main supply of the VF 5 unit MUST be switched OFF and ON again to read the new programming.
  • Page 4: Power Inputs

    PROGRAMMING AUTOMATIC DOORS FOR LIFTS Master and Slave. ON: Master. The door control unit will execute instructions directly. Example: photocell activation will cause the doors to re-open immediately without control of the door control unit. OFF: Slave. There is no automatic reopen movements. The doors will only react to instruction given by the main lift controller.
  • Page 5: Other Inputs

    SERIAL PORT CONNECTION 17 / 18 / 19 / 20 Photocell. One of the most relevant characteristics of this control is the optional incorporation of the Fermator photocell. It is composed by a emitter and receptor infrared. CONNECTION OF THE PHOTOELECTRIC DETECTOR...
  • Page 6 The doors will open slowly for the first operation after power has been removed from the door control unit. Autoadjustment only needs to be used when setting the initial parameters or when changes such as connecting or removing the Fermator photocell are made.
  • Page 7 The purpose of the encoder, which is situated inside the motor, is to inform the control of the exact position and speed of doors. Compatibility with Fermator asynchronous motor. - The VF5 encoder connector is prepared to connect the ENCODER...
  • Page 8: Programming Examples

    PROGRAMMING EXAMPLES AUTOMATIC DOORS FOR LIFTS MASTER: 1 INPUT • - Configuration 1. ON: 1 Input. 2. Depends on type of door. 3. Depends on type of door. 4. ON: Master. - Inputs 1. 8 Close. Closes the doors with voltage between terminals 8 & 10.
  • Page 9 LEARNING PHASE OF THE DOOR OPERATOR AUTOMATIC DOORS FOR LIFTS Switch on the VF door controller. Button O/I in the side of the box. Cables. 5 / 6 / 7 Connect the 230 V AC mains supply to the controller If they are connected, disconnect the following connections: 8-12: Input signals.
  • Page 10 The motor voltage has to be checked with the Fermator programming tool. You should change the motor if no movement is made when the voltage is present.
  • Page 11 - Press the «TEST» button and establish the potentiometers (open speed, close speed and the safety force) in order to get the required adjustment. Information: The VF parameters could be adjusted with the Fermator programming tool. TEST OF THE PHOTOCELL Remove the photocell wiring from any place where there are “electric noises”...
  • Page 12: Troubleshooting

    PROBLEMS WITH THE PHOTOCELL AUTOMATIC DOORS FOR LIFTS The photocell is active intermitently. • - Check the “grounding” connection (6). - Check the correct plugs connection. (17 to 20). - Disconnect the photocell, make a complete open and close movement, connect again the photocell and try again.
  • Page 13 Adjust the belt tension and make the autoadjustment again. • The system gets power but doesn’t work and the led ON is off. - Check if both external fuse are burned and change it for another Fermator fuse (250 V, 4 A ceramic fast speed). •...
  • Page 14: Reference Data

    REFERENCE DATA AUTOMATIC DOORS FOR LIFTS POWER SUPPLY • AC voltage range 230 V AC +10%, 15% • Frequency supply 50...60 Hz • Stand by power 50 mA • Nominal power (PM motor) 0,21 A 20 W • Maximum peak power 1,31 A 170 W INVERTER...
  • Page 15: Declaration Of Conformity

    DECLARATION OF CONFORMITY AUTOMATIC DOORS FOR LIFTS Tecnolama, S.A. Ctra. Constantí, Km 3 43204 REUS (Spain) Here with declares that the products mentioned below conform with the following E.U. council directives: European Directive 2014/30/EU on Eelectromagnetic Compatibility (EMC) in accordance with the Product family standard for lifts, escalators and moving walks EN12015: 2014 and EN12016: 2013 VF 5 Electronic Module (10/31700972_M1)