- Configuration
1. ON: 1 Input.
2. Depends on type of door.
3. Depends on type of door.
4. ON: Master.
- Inputs
1. 8
Close.
2. 17...20 Photocell.
3. 21-23
Reopening.
4.
Obstacle.
5. 25-23 Slow Closing. Closes regardless of the state of the photocell.
- Priorities
1.
21-23
Reopening.
2.
Obstacle.
3. 25-23 Slow Closing
4. 17...20 Photocell.
5. 8
Close.
- Configuration
1. ON: 2 Inputs.
2. Depends on type of door.
3. Depends on type of door.
4. ON: Slave.
- Inputs
1. 8
Close.
2. 12
Open.
3. 17...20 Photocell.
4. 21-23
Reopening.
5.
Obstacle.
6. 25-23 Slow Closing. Closes regardless of the state of the photocell.
- Priorities
1.
12
Open.
2. 21-23
Reopening
3. 25-23 Slow Closing.
4. 8
Close.

PROGRAMMING EXAMPLES

Closes the doors with voltage between terminals 8 &
10. Open the doors when the voltage between
terminals 8 & 10 is removed.
Doors will reopen if the photocell beam is broken.
Doors will not close if this signal is active.
Door will re-open if an obstacle is detected by the
motor ceasing to rotate.
Closes the doors with voltage between terminals 8 &10.
Open the doors with voltage between terminals 12 &
10.
Does not re-open the doors when activated but provides
signal to main controller via the Photocell
relay.
Doors will not close if this signal is active.
Door will not re-open if an obstacle is detected by the
motor ceasing to rotate.
VF5