T3AFG5 / T3AFG10
Function / Arbitrary Waveform Generators
Quick Start Guide
Version 1.1
September, 2018

Advertisement

loading

Summary of Contents for Teledyne T3AFG5

  • Page 1 T3AFG5 / T3AFG10 Function / Arbitrary Waveform Generators Quick Start Guide Version 1.1 September, 2018...
  • Page 2: Table Of Contents

    Using In-line Help System ................12 © 2018 Teledyne LeCroy, Inc. All rights reserved. Teledyne Test Tools is a brand and trademark of Teledyne LeCroy, Inc. Other product or brand names are trademarks or requested trademarks of their respective holders. Specifications, prices, availability and delivery subject to...
  • Page 3: General Safety Summary

    Before connecting to the instrument, read the manual to understand the input/output ratings. Do not operate with suspected failures. If you suspect that the instrument is damaged, contact the Teledyne LeCroy service department immediately. Do not operate in wet/damp conditions.
  • Page 4 Safety Terms and Symbols The following terms may appear on the instrument: DANGER: Direct injury or hazard may occur. WARNING: Potential injury or hazard may occur. CAUTION: Potential damage to instrument/property may occur. The following symbols may appear on the instrument: Alternating Earth Protective...
  • Page 5 AC Power Input Voltage & Frequency: 100-120 V at 400 Hz or 100-240 V at 50/60 Hz Automatic AC selection. Power Consumption: 50 W maximum Mains Supply Connector: CAT II per IEC/EN 61010-1:2010, instrument intended to be supplied from the building wiring at utilization points (socket outlets and similar).
  • Page 6: Adjustment Handle

    Handle Adjustment Users can adjust the handle to the required position by pulling the mounting points outward and adjusting the handle position. Handle Adjustment Carrying Position Horizontal Position 4 Quick Start...
  • Page 7: Front Panel

    Front Panel The picture below shows the front panel composition: 5. Waveform Option Area 6. Number Keys Adjust Knob 3. LCD Display 4. Back Key 2. USB 8. Arrow Keys Host 9. Channel 11. Mode / 1. Power Button Control/Out Utility 12.
  • Page 8 Waveform Options Sine ----Sine Wave Provides a sine wave output. The backlight lights when the key is being used. The “Frequency/Period”, “Amplitude/High level”, “Offset/Low level”, “Phase” of the sine wave can be adjusted. Square ----Square Wave Provides a square wave output. The backlight lights when the key is being used.
  • Page 9 Arb ----Arbitrary Waveform - Continued The “Frequency/Period”, “Amplitude/High level”, “Offset/Low level”, ● “Phase” of the arbitrary waveform can be adjusted. 6. Number Keys The key pad numbers from 0 to 9, radix points “.”, symbol keys “+/-”, are used to input parameters. If a negative number is required then input a “-” symbol before you input the numbers.
  • Page 10 Sweep Used to generate “sine wave”, “square wave”, ● “sawtooth waveform” and “arbitrary waveform” swept signals. It supports “Linear” and “Log” sweep types. It supports “Internal” , “Manual” and “External” trigger sources. The backlight of the key lights when the key is being used. Burst Used to generate “sine wave”, “square wave”, “sawtooth waveform”...
  • Page 11: Back Panel

    Back Panel 1. AC Power Supply Input The waveform generator can input two different kinds of AC power supply: 100 - 240 V at 50/60 Hz or 100 - 120 V at 400 Hz The fuse type is: 1.25 A, 250 V 2.
  • Page 12: User Interface

    User Interface The example below shows the interface when selecting sine wave. Current Function Displays the current function name. For example: “sine” in this example. Waveform Display Area Shows the channel’s current waveform. Frequency Shows the channel’s waveform frequency. Adjust the frequency value by selecting the frequency menu then use the number keypad...
  • Page 13 The example below shows the interface when selecting sine wave. Load Shows each channel’s load setting. High Resistance: displays “Hi-Z” Load display default is “50 Ω” Offset Shows the channel’s DC offset value. Adjust the offset value by selecting the Offset menu then use the number keypad or knob.
  • Page 14: Using In-Line Help System

    Using the Built-In Help System To access the built-in help system, press the Help key, then use the arrow keys to choose the help item you want. Finally, press Select to obtain help. The help listings are as follows: 1. View the instrument information 2.
  • Page 16 The Teledyne Test Tools brand expands on the Teledyne LeCroy product portfolio by adding a comprehensive range of test equipment solutions for its customers. The new range of product solutions deliver engineers with a broad range of quality test solutions that enables speed to market product validation and design.