Koine 35 Quick User Guide
ERR 00:
-
The drive motor is open or the mixing chamber is not 90º
•The main power cord from the motor to the feeding wheel switch disconnected.
•The emergency stop button is in.
•The control panel has a malfunction.
ERR 01:
-
The electronic control system (inverter) has over heated, wait for it to
cool down and try again.
ERR 02:
-
The mixing paddle and stator/rotor drive motor has over heated, it is
running too hard. Wait for it to cool down and try again.
ERR 03:
-
The drive motor is jamming up, it cannot turn the stator/rotor. Check
that the material you are pumping is not too stiff a mix. If using a long length of
hose, shorten it. Finally, make sure that the mixing chamber does not have dry
material built up inside it, the mixing paddle could be binding up
ERR 04:
-
The drive motor is being overloaded. Make sure your material is not
too stiff, make sure you have 220 volts of current and 30 amps, slow down your
pumping speed.
ERR 05:
-
The water pump and the compressor have been turned on for more
than 15 minutes and during this period they have not been used. Or the com-
pressor air hose system is leaking somewhere.
ERR 06:
-
The compressor is seized up or the switch on the compressor has not
been turned on.
ERR 07:
-
The unit is shorting out, this is a very dangerous situation. Check for
water in the control panel or loose wires. Contact IMER service @ 800-275-5463,
or email to: mace@imerusa.com.
ERR 08:
-
Voltage is too low. Inverter is not receiving enough single phase cur-
rent to power on.
ERR 09:
-
The loading hopper feeding blade is blocked or turning too slowly.
Clean out any obstructions. It could also be that water has backed up into the
feeding hopper. Clean it and dry it out thoroughly.
"BLOC":
-
The stator/rotor is jammed up, or the material hose is jammed up,
material cannot move through either one.
"H2O":
-
The volume of water being supplied to the pump is too low to operate
the pump correctly. Get a better water supply.
"VOLT":
-
Blue light switches off rapidly. Voltage too high and the inverter is
shutting down to avoid damage.
Koine 35 Error Code Table
These error messages are shown on the inverter
display panel when specific situations arise: