Download Print this page

Opticon CRD-13 Quick Start Manual page 2

Advertisement

CRD-13 Basic Specifications
Parameter
Physical
Size
Features
Weight
Control
CPU
Section
Internal
Memory
Comm.
Section
IrDA
1
(H-13-CRD-13)
Comm.
RS-232C
2
Section
(CRD-13- Host)
USB
Power
Main Power
Supply
Supply
Section
Current
Consumption
Charging Time Approx. 3 hours
Power Feed
For Charging the
Section
Portable Terminal
3
Display
LED
Section
Durability Operating Temp. -10 deg. C to 50 deg. C
Operating Humidity 25% to 85% (non-condensing)
Storage Temp. -20 deg. C to 60 deg. C
Storage Humidity 20% to 90% ( non-condensing)
Charging Temp. 0 deg. C to 40 deg. C
Shock
Endurance
Baud Rate: Theoretical figure
1
RS-232C baud rate synchronizes with IrDA baud rate.
2
Can be switched ON/OFF using the detection switch.
3
To avoid communication problems between the cradle
and a portable terminal, keep the IrDA window clean.
Memo
IrDA communication performance may decline due
to excessive ambient light (especially under strong
sunlight or inverted fluorescent light.)
AC adapter Basic Specifications
Parameter
AC
Input
adapter
Output
Specifications
×
×
(H)64.9
(W)70.0
(D) 144.4mm
Approx. 125g
32bit RISC CPU
ROM : 256KB
RAM : 64KB
IrDA Ver1.2 (physical layer only)
Baud rate: SiR : 9600 to 115.2kbps
FiR : 4Mbps
Baud rate: 9600 bps
19.2, 38.4, 57.6,115.2 kbps
Ver2.0 (Full-Speed)
Virtual COM
AC Adapter : DC 6.0V, 2.0A
When communicating : 110mA or less
(DC 6.0V, when not charging)
Max: 1.7A or less
(when charging a portable terminal)
Output: DC 6.0V (Typ.)
Electrical terminals : + / -
Power Supply : Red / Green
Data communication : Red / Green
Dropped once from each of 6
angles onto concrete from a height
of 75cm with no defects found.
Specifications
Power Voltage: AC 90 to 265V
Current Consumption : 0.5A max.
Power Voltage: 5.7 to 6.3V
Maximum current: 2.0A max.
Overview
Detailed View
No.
Part
Power Supply
Status LED
Comm. Status LED
IrDA
Communication
Window
Detection Switch
Portable Terminal
Charging
Terminals
Guard Bar
Product Label
DIP Switches
DC jack
USB Connector
RS-232C Connector
Function
Alerts users to the status of
power distribution from the
AC adapter to the cradle.
Alerts users to the status of
the IrDA data transmission.
The cradle communicates
with the designated portable
terminal through the IrDA
communication window.
Terminal detection switch
to change the settings of
the power feeding section.
Electrical terminals for power
distribution to the designated
portable terminal.
To protect the USB, RS-232C
cables and DC jack.
DIP switches to configure the
settings of the CRD-13. Refer to
the DIP Switch Configuration
for details.
DC6.0V power supply jack.
Please use the AC adapter.
Connector for USB interface.
Connector for RS-232C cable.

Advertisement

loading