  • Page 1 ULTRASONIC MESH NEBULIZER Instructions Read thoroughly before operating the nebulizer Save these instructions for future reference...
  • Page 3 Sonair Introduction ..............2 Safety Precautions ..............4 Parts and Components ............7 Preparing the Device ............... 8 Operating Instructions .............10 Cleaning and Disinfecting ............13 Storage and Maintenance ............15 Troubleshooting ..............17 Device and Label Symbols ............ 19 Electromagnetic Compatibility ..........20 Limited Warranty ..............
  • Page 4 By selecting this product, you have chosen a high quality, innovative device. Before using the Sonair Nebulizer for the first time, please read through this manual carefully. If you still have any questions regarding its use, visit the A.M.G. Medical website or contact our Customer Service team at 1-800-363-2381.
  • Page 5 The Sonair Nebulizer is an easy to use device with only One-Touch Operation. This compact nebulizer is portable allowing you the flexibility to use at home or at work. Sonair’s size also makes it perfect for travel, it can fit into a brief case, purse or backpack.
  • Page 6 DO NOT USE THE SONAIR NEBULIZER WITH: Pentamidine, Pulmonary Edema Patients, Acute Asthma, and Acute Pulmonary Infarction Episodes • This nebulizer is a medical device. Only use medications as prescribed and instructed by your healthcare professional. • Only use the nebulizer for its intended purpose, for inhalation therapy.
  • Page 7 • Do not shake the nebulizer during operation. • Do not drop the nebulizer. • Never use in environments with high humidity (eg: bathroom) • Never use in rooms where aerosols (sprays) are used or pure oxygen is being administered. Do not use it near highly flammable substances, gases or explosives.
  • Page 8 • Never use liquids which contain ester, fatty or suspended particles. Only use healthcare professional prescribed medications for nebulizing. • Close supervision is necessary when this product is used by or near children and/or persons with special needs. Never use this unit when sleeping or drowsy.
  • Page 9 Mini USB Port Medication Cup Mouthpiece Spray Nozzle Mask (2 included) Power Switch USB Cable Unit Accessory Bag...
  • Page 10 Remove the unit and all accessories from package.When using the Sonair Nebulizer for the first time or after not using it for a long period of time, remember to clean and disinfect the nebulizer including the medication container, mesh metal, spray nozzle, mask, and mouthpiece prior to use.
  • Page 11 The indicator light will turn green during charging, and will turn off when the unit is fully charged. Note: Charge the Sonair Nebulizer at least once per month even when not being used (in storage). 3. Insert the mouthpiece (a) or the mask (b) directly into...
  • Page 12 Wash hands with soap and warm water, then dry completely with a clean towel. Ensure that the medication cup and accessories have been cleaned and / or disinfected before first use, as well as after the last treatment of the day. Refer to the cleaning and disinfecting instructions in this manual.
  • Page 13 4. Nebulization 1) Click power key to start nebulization 2) Hold the device so that the medication stays in contact with the nebulization mesh. 3) If using the mouthpiece (a), bring it into mouth and close lips slightly to facilitate nebulized medication flowing deep into the bronchial tubes.
  • Page 14 6) Inhale the liquid medication mist. Always be calm and relaxed when you inhale. If you want to lay in bed for treatment, it is suggested to put a pillow behind your back so that you can keep the spine straight. Breathe in slowly and deeply so that the nebulized medication can reach fully into the bronchial tubes.
  • Page 15 The following items should be cleaned after each use: nebulizer nozzle, medication cup, metal mesh in nebulizing head, mouthpiece and mask. Before cleaning, turn off the device by pressing the power key Remove all components including the mask, mouthpiece and medication cup from the device.
  • Page 16 Immediately after cleaning, dry the nozzle, medication cup and accessories with medical gauze. Note that the metal mesh in the nebulizing head should not be touched with any sharp or rough objects. Gently dry the water inlet and outlet of the nebulizing head with a medical swab.
  • Page 17 Storage • Store the device in a clean, dry place and protect it against heat, sunshine, and moisture. • Make sure the nebulizer has been cleaned and sterilized thoroughly after each use. • Make sure that the nebulizer and all accessories are completely dry.
  • Page 18 Maintenance Do not attempt any repairs to the device or any of its accessories. Contact us at 1-800-363-2381 for repair information. • The manufacturer will not be held responsible for the results of maintenance or repairs by unauthorized persons. • Check the device before each use for signs of wear and/or damage.
  • Page 19 If your device does not seem to be operating correctly, refer to the chart below to determine what may be wrong. If none of these measures correct the problem, please contact A.M.G. Medical Customer Service at: 1-800-363-2381, between 8:30 AM and 5 PM EST. Trouble Possible Cause / Solution Nebulizer does...
  • Page 20 Trouble Possible Cause / Solution Low nebulization 1) Tilt the device towards yourself to immerse the nebulizing head side with medication in order to make full use of it. 2) The nebulizer (nozzle / metal mesh) may be blocked. Clean nebulizer (nozzle / metal mesh).
  • Page 21 These symbols may appear on your device, instructions or packaging. Separate collection for Read this manual / General imperative electrical and Consult Instructions electronic equipment before use Upward Do not disassemble Keep device dry Be careful of The application Power key electric shock part of Type BF Caution / Consult accompanying documents before use...
  • Page 22 Electromagnetic Compatibility Guidance and Manufactures Declaration – Electromagnetic Emissions This device is intended for use in the electromagnetic environment specified below. The user of this device should assure that is used in such an environment. Electromagnetic Environment Emission Test Compliance Guidance RF emissions Group 1...
  • Page 23 Electromagnetic IEC 60601 Test Compliance Immunity Test Environment Level Level Guidance Electrostatic ± 6 kV contact ± 6 kV Floors should be wood, discharge contact concrete or ceramic tile. ± 8 kV air GB/T 17626.2 If floors are covered with ±...
  • Page 24 IEC 60601 Compliance Electromagnetic Immunity Test Test Level Level Environment Guidance Power 3 A/m 3 A/m Power frequency magnetic field frequency 50 Hz 50 Hz should be at levels characteristic magnetic field 60 Hz 60 Hz of a typical location in a typical GB/T 17626.8 commercial or hospital environment.
  • Page 25 NOTE: - At 80 MHz and 800 MHz, the higher frequency range applies. - These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. * Field strengths from fixed transmitters, such as base stations for radio (cellular/ cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
  • Page 26 This device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and this device as recommended below, according to the maximum output power of the communications equipment.
  • Page 27 A.M.G. Medical Inc. warrants the device to be free from defects in material and workmanship for a period of one (1) year, to be proven by means of the sales receipt or invoice. This warranty is valid for the original purchaser only. Any alterations, abuse, misuse or accidental damage voids this warranty.
  • Page 28 Power Supply DC 2.4V Built in lithium battery Power Consumption < 4.0 W Nebulization Rate > 0.35 ml / minute MMAD 1~5 µm Working Frequency 120 kHz ± 10 kHz MMAD 2.5 ± 30% µm Medication Liquid ≤ 45°C Temperature Medication Cup 10 ml Capacity...
  • Page 32 Questions? Comments? 1-800-363-2381 • www.amgmedical.com Made and printed in China for / Fabriqué et imprimé en Chine pour : A.M.G. Medical Inc. 8505 Dalton, Montréal, QC H4T 1V5 Canada • 1-800-363-2381 Rev1 0618 P/N 861-705460...