Alemite 3575-D Manual

Oil control handle with mechanical meter

Advertisement

Quick Links

Introduction

Thank you for purchasing an Alemite 3575
series Control Handle complete with me-
chanical meter. It has been designed to accu-
rately dispense, measure and control flow of
engine oil, gear oil, automatic transmission
fluid, and anti-freeze/anti-boil fluids.
Please read and retain this instruction
manual to assist you in the operation and
Maintenance of this quality product.

General Information

This manual assists you in operating and
maintaining your new oil control handle, and
the information will help you ensure many
years of dependable performance with trouble
free operation.
Please take a few moments to read through
this manual before installing and operating
your new oil control handle. If you experience
problems with this product, refer to the trou-
bleshooting sections of this manual. If you re-
quire further assistance please contact your lo-
cal Alemite distributor or authorised Alemite
service center.

Important Information

Read This Information Carefully Before
Use.
Your safety is important to us. Read and
follow all safety instructions.
Some of these instructions "Cautions" alert
you to the potential for personal injury.
"Notices" throughout this manual advise of
potential practices or procedures which may
cause damage to your equipment.
Do not install in a rigid pipe in-line system.
Do not install with a shut-off valve on the out-
let side of the meter. Damage may occur to the
housing cover.
Ensure all operators have access to adequate
instructions about safe operating and mainte-
nance procedures.
Form 671086
Oil Control Handle with Mechanical Meter
C a u t i o n
Do not point nozzle at yourself or
anyone else.
Do not exceed pressure rating of any
component installed in system.
Install an adequate pressure relief
valve for operator safety.
Operating pressure:
0-200 psi (0-13.79 bar)
Line pressure between pump and the
control handle trigger valve must not
exceed 1,500 psi (103 bar).
Do NOT modify the auto
non drip nozzle.
Failure to comply could result in
minor or moderate injury.
Part number
Alemite, LLC
167 Roweland Drive, Johnson City, Tennessee, 37601
www.alemite.com
mechanical meter (Model 3575-A shown)
3575-A
Quarts meter with rigid extension
3575-B
Quarts meter with flexible extensions
3575-C
Liters meter with rigid extension
3575-D
Liters meter with flexible extension.
3575-A
3575-B
3575-C
3575-D
Figure 1 Oil control handle and
Description
SER 3575-A
Initial release (10-15)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3575-D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alemite 3575-D

  • Page 1 3575-D Oil Control Handle with Mechanical Meter Introduction C a u t i o n Thank you for purchasing an Alemite 3575 Do not point nozzle at yourself or series Control Handle complete with me- anyone else. chanical meter. It has been designed to accu-...
  • Page 2 4 Remove valve spring (30), valve seal as- sembly (29) and plunger (28). When fluid flows through the handle the outlet nozzle will automatically open. When the fluid flow stops the outlet nozzle will auto- matically shut. Initial Release 10-15 Alemite, LLC...
  • Page 3 Lightly lubricate the valve cam After assembly ensure handle (24) before assembly. latch operates correctly. 2 Place O-Ring (23) onto valve cam (24). Notice Cut out section in middle of valve cam (24) must face inlet swivel (33). Alemite, LLC Initial Release 10-15...
  • Page 4 8 Fit register assembly (4) into register housing (6) and replace 4 x Phillips head Notice screws (7). Refer to Meter Disassembly Parts A and B. 5 Remove facia (2). Initial Release 10-15 Alemite, LLC...
  • Page 5 SER 3575A Mechanical Meter Oil Control Handle Alemite, LLC Initial Release 10-15...
  • Page 6 Cam, Valve 1)2) Repair kits Part no. Note Description Notes 393814-1 Kit, Major Service 393814-2 Kit, Valve Service Includes items on Figure 4. 393814-3 Kit, Swivel Assembly (NPT) 393814-4 Kit, Rigid Extension 393814-5 Kit, Flexible Extension Initial Release 10-15 Alemite, LLC...
  • Page 7 1.16 kg ( 2.55 lbs) Fluid Compatibility: Transmission Fluid, Anti-freeze / Anti-Boil Mixture. (Maximum Viscosity SAE140) 25.8 cm (10 inch) Long x 9.5 cm ( 3.7 inch) Dimensions: High, x 11 cm (4.33 inch) Wide (Dimensions without extension) Alemite, LLC Initial Release 10-15...
  • Page 8    U              Bob Hoefler   Robert Hoefler  Director Product Development and Product Engineering St. Louis, MO   Initial Release 10-15 Alemite, LLC...

This manual is also suitable for:

3575-c3575-b3575-a3575 series

Table of Contents