Setting Close Direction
The direction of motor rotation depends on mounting position and/or how the main input power phases are
wired. This setting is used to insure the door is closing and opening according to the input commands.
NOTE: Make sure door is in Mid-Travel.
1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.
2) Press SET/CLEAR to begin the calibration procedure and advance to the next screen. Figure 3.
3) Briefly press the CLOSE key. (Pressing the Scroll key at this point will exit this control function.)
• The display will read " DID DOOR CLOSE? " Figure 4.
4) Press SCROLL key (up or down) to toggle between YES and NO. Figure 5.
• If YES is selected, no change to operator calibration is made. If NO is selected — It will change the
operator's down direction.
5) Press the SET/CLEAR key.
Section 6: Operator Setup Procedure
Figure 2
Figure 3
Figure 4
Figure 5
SCROLL KEY
SET CLOSE DIR
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
PRESS CLOSE KEY
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
DID DOOR CLOSE?
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
YES
NO
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
OPEN
CLOSE
STOP
6.3