5 - Using the Settings Panel

INFORMATION page

1 Status display area
This shows the current status of the unit.
Item displayed
Meaning
Software Version
This is the software version.
This is the firmware version used
Firmware version
by the connected unit.
This is the name of the connected
Device
unit. (No Device is shown when no
device is connected.)
This shows the name of the
Clock Source
currently selected clock source.
This shows the current sampling
Sample Rate
frequency.
This shows the sampling clock
status.
Good: There are no problems.
Unlocked (or No Signal):
Phase Error:
Clock Source Status
Sample Rate Mismatch:
OPTICAL A Input Status This shows the OPTICAL input
status.
Good: There are no problems.
Unlocked (or No Signal):
Phase Error:
OPTICAL B Input Status
(SERIES 208i only)
Sample Rate Mismatch:
* Note about the sample rate of this unit
i Win: Set the same sample rate for both the Playback and
Recording tabs of the Sound Properties in Control
Panel screen.
i Mac: Set the sample rate in the Audio Devices window of
Audio MIDI Setup.
20
TASCAM SERIES 102i / SERIES 208i
There is no valid signal or it is
disconnected.
This unit and the device that
is optically connected are not
synchronized.
This unit and the device that
is optically connected have
different sample rates.
There is no valid signal or it is
disconnected.
This unit and the device that
is optically connected are not
synchronized.
This unit and the device that
is optically connected have
different sample rates.
NOTE
i When the unit and the computer are not connected, "No
Device" is shown for the "Firmware Version" and "Device"
items.
i When the 2 Sample Clock Source item is set to "Internal", the
Clock Source Status item will appear dimmed as "----------".
2 Sample Clock Source
Use this to set the sampling clock source.
Option
Meaning
The unit's built-in clock is always
INTERNAL
used.
OPTICAL A
The clock signal input through the
OPTICAL IN (S/MUX) connector
is used.
If the connected device is a
OPTICAL B
TASCAM device and 3 Rate
(SERIES 208i only)
setting is "Auto - TASCAM Device",
the input clock signal will be
automatically identified and set.
WORD
The clock signal input through the
WORD IN connector is used.
(SERIES 208i only)
NOTE
i When set to OPTICAL A, OPTICAL B or WORD, if no
signal is input through the corresponding connector or
synchronization becomes impossible, the status will appear
in the Clock Source Status item and this unit's STANDBY
indicator will blink.
i When connecting multiple digital devices to the SERIES 208i,
synchronize them to a system word clock and input word
clock supplied by the master clock device to the SERIES 208i.
i After changing the clock source, proper continuation of
playback/recording might not be possible, so you should
restart the playback/recording software that you are using.
3 Rate items
Use these to set the connected OPTICAL (S/MUX) sample
rates.
If the connected device is also a TASCAM product, select
"Auto - TASCAM Device" to set this automatically.
Options: Auto - TASCAM Device, Manual - 44.1kHz/48kHz,
Manual - 88.2kHz/96kHz, Manual - 176.4kHz/192kHz
4 Buffer Size (Windows only)
The Windows driver for the unit stores the audio signals
transferred to and from the computer temporarily in a buffer.
This buffer size can be adjusted.
Smaller buffer sizes result in less audio signal delay (latency),
but require high-speed processing by the computer.
If the processing cannot keep up, for example, due to other
system operations, clicking and popping noises might occur
and the audio signal might even drop out.
Increasing the buffer size will stabilize operation and
suppress negative effects on audio signals, but the delay in
audio signals sent to the computer will increase.
You can use the slider on the panel to adjust the buffer size,
according to the use conditions.
Use the slider to select fixed values that increase from left to
right.
Options: 4 Samples, 8 Samples, 16 Samples, 24 Samples,
32 Samples, 64 Samples, 128 Samples,
256 Samples, 512 Samples, 1024 Samples,
2048 Samples

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

102i series