information is provided before and during a dive when the computer is set in Air/Nitrox or
Trimix:
The selected O
% (and possible helium %)
2
CNS% and OTU
Audible notification when CNS% reaches 80%, then notification when 100% limit is
exceeded
Notifications when OTU reaches 250 and then again when 300 limit is exceeded
Audible alarm when pO
Audible alarm when pO
WARNING: WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE MAXIMUM
LIMIT IS REACHED, YOU MUST IMMEDIATELY TAKE ACTION TO REDUCE OXYGEN
EXPOSURE. Failure to take action to reduce oxygen exposure after a CNS%/OTU warning is
given can rapidly increase the risk of oxygen toxicity, injury, or death.

3.28. Tank Pressure

Comments for radio approval
This functionality is partially available. Check separate instruction Test Modes for
D5_DW182.docx.
Your Suunto D5 can be used with multiple Suunto Tank PODs for wireless tank pressure
transmission.
To install and pair a Suunto Tank POD:
1. Install the Tank POD as described in the Tank POD quick guide.
2. Wait for green LED on Tank POD to flash.
3. If your Suunto D5 has a blank screen, press any key to activate it.
4. Hold your Suunto D5 close to the Tank POD.
5. After a few seconds, a menu pops up on the screen showing the Tank POD serial number,
battery status and the tank pressure. From the menu, select the correct gas for that Tank
POD.
WARNING: The battery level indication shown when pairing the Tank POD is an
approximation only. The POD battery may deplete faster than the indication suggests.
Repeat the procedure above for additional Tank PODs and select different gases for each
POD.
Alternatively, you can select which Tank POD to use with each gas by selecting a Tank POD
for the gas in question in the Gas(es) menu. When using this method, ensure the Tank POD
has been activated by ensuring there is tank pressure reading in screen and that it is within
range. In the menu, the Tank POD is identified by the serial number printed on the Tank POD.
In the dive main views, only one tank pressure is shown and corresponds to the active gas.
When the gas is changed, the displayed tank pressure is also changed accordingly.
WARNING: If there are several divers using Tank PODs, always check before you dive
that the POD number of your selected gas corresponds to the serial number on your POD.