Drain And Recirculation Pump - GE HTW200ASKWW Service Manual

2015 27" top load washer
Hide thumbs Also See for HTW200ASKWW:
Table of Contents

Advertisement

Drain And Recirculation Pump

The drain pump is located on the right side
of the bottom of the tub. It is mounted
directly to the tub secured by three (3) 3/8
th
hex head bolts.
The GTW680 model has a recirculation
pump located at the front of the bottom of
the tub. It mounts to the tub the same as
the drain pump.
Video Link
Drain Pump
Both pumps are 120 VAC.
The approximate resistances of the pumps
checked from J512 board connector are:
Drain pump – 13.2 ohms
Recirculation pump – 31.7 ohms
Video Link
Recirculation Pump