Hundure RAC-510PE Hardware Manual

Hundure RAC-510PE Hardware Manual

Standalone access controller

Advertisement

RAC-510/511PE
Standalone Access Controller
Hardware Manual
Version 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAC-510PE and is the answer not in the manual?

Questions and answers

Summary of Contents for Hundure RAC-510PE

  • Page 1 RAC-510/511PE Standalone Access Controller Hardware Manual Version 1.0...
  • Page 2: Table Of Contents

    5.2.6 Set Door Relay Mode .................28 5.2.7 Set Unlock Door Time.................29 5.2.8 Door Sensor Detection Time ..............30 5.2.9 Enable/Disable Conditional Unlock Door Settings ........31 5.2.10 Compare valid Address ................32 5.2.11 Advanced Settings 1.................33 5.2.12 Advanced Settings 2.................34 RAC-510/511PE Hardware manual HUNDURE...
  • Page 3 5.2.24 Door Open Mode ..................46 5.2.25 Slave Reader Setting................47 5.2.26 System Initialization ..................48 Chapter 6 Testing ......................49 Chapter 7 Troubleshoot .....................50 Appendix..........................51 Appendix A:RAC-510/511 Function List..............51 Appendix B:Wiring Material Requirements...............54 Revision History Version Description V1.0 First Edition RAC-510/511PE Hardware manual HUNDURE...
  • Page 4: Chapter 1 Product Overview

    Chapter 1 Product Overview 1.1 Package Contents C o n t r o l l e r x 1 Quick Start Guide x 1 Screw x 3 Base x 1 Cable x 1 RAC-510/511PE Hardware manual HUNDURE...
  • Page 5: Features

    1.2 Features Supports standalone operation Memory capacity 1,024 cardholders / 800 events. Provides RS-485 communication interface for management through PC.(RAC-510PE) Provides unlock door modes by card or card + PIN; programmable unlock door duration. Casing tamper proof detection and door ajar alarm. Programmable door sensor detection time Duress card/code setting.
  • Page 6: Specifications

    1.3 Specifications Model No. RAC-510PE RAC-511PE Read Format EM (125 KHz ) Read Range 6~8cm Slave Reader T2/Wiegand Input Ports 3 Sensors(Door SensorX1, Exit ButtonX1, Case SensorX1) Output Ports(Built-in ) Relay X 1(Door Lock) Output Ports(External) O.C Output X2 (Door Lock/Alarm, external ACU-30)
  • Page 7: Chapter 2 Physical Dimension

    Chapter 2 Physical Dimension 2.1 Dimension Scale: mm RAC-510/511PE Hardware manual HUNDURE...
  • Page 8: Appearance Introduction

    2.2 Appearance Introduction Case Sensor ID Settings Kindly refer to the pin assignments below3.2.2 Built-in Relay When Electric Bolt Lock is used, kindly connect the wire to COM RAC-510/511PE Hardware manual HUNDURE...
  • Page 9 NC contacts. When Electric Strikes Lock is used, kindly connect the wire to COM and NO contacts. RAC-510/511PE Hardware manual HUNDURE...
  • Page 10: Chapter 3 System Configuration & Wire Connections

    Chapter 3 System Configuration & Wire Connections 3.1 System Configuration RAC-510 RAC-510/511PE Hardware manual HUNDURE...
  • Page 11 RAC-511 RAC-510/511PE Hardware manual HUNDURE...
  • Page 12: Wire Connections

    3.2 Wire Connections 3.2.1 Communication Interface Connection The device RAC-511 does not provide RS-485 functionality (the wires' colors are Yellow, Blue) RAC-510/511PE Hardware manual HUNDURE...
  • Page 13: Acu-30 Wire Diagram

    3.2.2 ACU-30 Wire Diagram The device RAC-511 does not provide RS-485 functionality (the wires' colors are Yellow, Blue) RAC-510/511PE Hardware manual HUNDURE...
  • Page 14: Alarm Connection

    3.2.3 Alarm Connection With ACU-30 for digital output RAC-510/511PE Hardware manual HUNDURE...
  • Page 15: Electronic Lock Setup

    3.2.4 Electronic Lock Setup Without ACU-30 for digital output With ACU-30 for digital output RAC-510/511PE Hardware manual HUNDURE...
  • Page 16: Exit Button/Door Sensor Connection

    3.2.5 Exit Button/Door Sensor Connection Without ACU-30 for digital output RAC-510/511PE Hardware manual HUNDURE...
  • Page 17 With ACU-30 for digital output RAC-510/511PE Hardware manual HUNDURE...
  • Page 18: Slave Reader Connection

    3.2.6 Slave Reader Connection RAC-510/511PE Hardware manual HUNDURE...
  • Page 19: Power Supply Connection

    3.2.7 Power Supply Connection Note:To avoid interference self- detection of sensitive keypad , please do not touch keypad when input power. RAC-510/511PE Hardware manual HUNDURE...
  • Page 20: Chapter 4 Installations

    (B) Connect the wires in accordance with the wiring instruction below. (C) Make sure the back base and the controller upper cover guides are aligned. (D) Install the controller upper cover to the back base. (E) Fasten the screw onto the bottom of the controller. RAC-510/511PE Hardware manual HUNDURE...
  • Page 21: Chapter 5 Setting

    Chapter 5 Setting 5.1 ID Setting For RAC-510 only RAC-510/511PE Hardware manual HUNDURE...
  • Page 22: Function Settings

    PWR LED flashes red light After entering command, controller beeps once. Input the parameter settings for the command. NOTE: Command Code 93 clears the entire memory and deletes all card nos. Kindly take precaution before doing this operation. RAC-510/511PE Hardware manual HUNDURE...
  • Page 23: Add A Card Number

    Passwords are not allowed under shared mode,. Card number has not been given a password. Kindly be aware of the access mode. If card swipe with password is selected, password should be set while adding the new card number. RAC-510/511PE Hardware manual HUNDURE...
  • Page 24: Delete A Card Number

    5.2.2 Delete a Card Number Command Code 02. Deletes a single card number and also removes its access authorization. Master Card/Code (Default 30191000) Enter 02 Input Card Number Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 25: Delete All Card Numbers

    Command Code 03. Deletes all valid card numbers. Deleting all card numbers will remove all access authorizations and requires user to input new card numbers. Kindly take caution in performing this operation. Master Card/Code (Default 30191000) Enter 03 Enter 03 Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 26: Successive Addition Of Card Numbers

    Master Card/Code (Default 30191000) Enter 04 Initial Card No. Total no. of cards Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 27: Successive Deletion Of Card Numbers

    This command is only allowed to be performed under shared memory. Command Code 05 Successive deletion of card numbers. All access authorizations will be deleted as well. Master Card/Code (Default 30191000) Enter 05 Initial Card No. Total no. of cards Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 28: Set Door Relay Mode

    Pulse : Door relay will return to original position within the time user set. Toggle: Door relay will not return to original position until alarm relay has been activated again. Master Card/Code (Default 30191000) Enter 09 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 29: Set Unlock Door Time

    Default time is 4 sec. Time duration can be set from 1 to 600 sec. (System ignores parameters set to 0 or greater than 600 sec.; default time is applied.) Master Card/Code (Default 30191000) Enter 10 Unit is 0.01Sec. Unlock Door Duration Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 30: Door Sensor Detection Time

    Alarm Relay to alert the administrator or security personnel. To deactivate the Alarm Relay, input the disarm code(Default is 0000). Master Card/Code (Default 30191000) Enter 11 Unit is 0.01Sec. Detection Time Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 31: Enable/Disable Conditional Unlock Door Settings

    Command Code 12 Enter 1-9999 sec. to set conditional unlock door settings. The door can remain open until the allotted time. If parameter value is set to 0, then conditional unlock door function is deactivated. Master Card/Code (Default 30191000) Enter 12 Duration Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 32: Compare Valid Address

    Command Code 13 Allows user to set the compare valid address. Compare Valid address=(Compare valid code Index-1)X16+Compare valid code length. 0=Select All Only support standard card mode Master Card/Code (Default 30191000) Enter 13 Compare Valid Address Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 33: Advanced Settings 1

    Door Prop Disable Door Prop Detection +128 Example: Door prop. detection enable controller beeps on door prop and forced door open detection is disabled.1+64+0=65 to perform the mentioned functions. Master Card/Code (Default 30191000) Enter 20 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 34: Advanced Settings 2

    Keypad Tones Keypad Tones “ON” Enable Case Disable Case Sensor Sensor Enable Case Sensor +128 Example: Enable card seipe and keypad tones.16+32+0=48,Enter 48 to perform the mentioned functions. Master Card/Code (Default 30191000) Enter 21 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 35: Re-Swipe Card Check Time

    5.2.13 Re-swipe Card Check Time Command Code 22 Enables re-swipe card check time. This function restricts a card to be swiped twice under a specified time. Master Card/Code (Default 30191000) Enter 22 0:Disable 1~255 Sec. Duration Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 36: Sensor No/Nc Settings

    Exit Button NO/NC Exit Button ”NO” Door Sensor Door Sensor ”NO” NO/NC Door Sensor ”NC” Example: Exit Button as NO,Door Sensor as NO 1+0=1.Enter 1 to perform the mentioned functions. Master Card/Code (Default 30191000) Enter 23 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 37: Access Granted For Master Code

    5.2.15 Access Granted for Master Code Command Code 24 Sets valid access authorization to Master Code. Door opens when Master Code is entered. Master Card/Code (Default 30191000) Enter 24 0:NO Value 1:Yes Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 38: Set Date

    (00~63), mm stands for month (01~12), dd stands for date (01~31), and ww stands for week (01~07) For RAC-510 only Master Card/Code (Default 30191000) Enter 25 yy:mm:dd:ww Completed 01 for Monday,07 represents Sunday and so on… RAC-510/511PE Hardware manual HUNDURE...
  • Page 39: Set Time

    Command Code 26 Sets displayed time on the LCD display. Time format is hh:mm:ss where hh represents hour (00~23), mm for minutes (00~59) and ss for seconds (00~59). For RAC-510 only Master Card/Code (Default 30191000) Enter 26 hh:mm:ss Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 40: Enable/Disable Keypad

    Note: Do not disable keypad when you don’t have the Master Card. Master Code is required to enter command mode, hence disabling the keypads will lock you out of the command prompt. Master Card/Code (Default 30191000) Enter 27 0:NO Value 1:YES Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 41: Save Invalid Card No

    Command Cod 31 Allows user to save invalid card number. To record invalid card numbers, set parameter to 1, to ignore, set to 0. For RAC-510 only Master Card/Code (Default 30191000) Enter 31 0:NO Value 1:YES Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 42: Set Master Code

    “30191000”. To change, kindly follow the instructions below and input the new 10 digit master code. Whenever a device initialization has been performed, master code will be restored back to it default “30191000”. Master Card/Code (Default 30191000) Enter 90 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 43: Set Disarm Card/Code

    “0000”. To change, kindly follow the instructions below and input the new 10 digit or less disarm code/card. Whenever a device initialization has been performed, disarm code will be restored back to it default “0000”. Master Card/Code (Default 30191000) Enter 91 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 44: Set Duress Card(Code)

    To change, kindly follow the instructions below and input the new 10 digit or less duress code/card. Whenever a device initialization has been performed, duress code will be restored back to default “1190”. Master Card/Code (Default 30191000) Enter 92 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 45: Set Memory Mode

    1. Under compressed and shared memory mode, card number should be exactly 10 digits. 2. Successive addition and deletion of card number can only be performed under shared memory mode. This function is not applicable for compressed and standard mode. RAC-510/511PE Hardware manual HUNDURE...
  • Page 46: Door Open Mode

    Command Code 94 Allows user to change the access mode--- swipe card only, swipe card or key in card No., swipe card or key in card No.+ password. This function is only applicable when RAC-510/511 is used as an access controller. Master Card/Code (Default 30191000) Enter 94 Value Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 47: Slave Reader Setting

    Example: Slave reader with T2 interface, request check password and enable Anti-password function. 0+1+4=5, Input 5 and then setting completed. Master Card/Code (Default 30191000) Enter 96 Value Completed The function must to setup the slave reader. RAC-510/511PE Hardware manual HUNDURE...
  • Page 48: System Initialization

    On the initial installation, set the device’s parameter to its default settings before deployment. If the following problem arises: Abnormal operation User wants to clear all card numbers and passwords Master Card/Code (Default 30191000) Enter 99 Enter 99 Completed RAC-510/511PE Hardware manual HUNDURE...
  • Page 49: Chapter 6 Testing

    Step 6 After 4 sec, (default unlock door time), door relay deactivates and OK/ERR LED extinguishes. For other functions, kindly refer to the instructions on the succeeding chapters, or inquire your engineers. Step 7 For other functions, kindly refer to the instructions on the succeeding chapters, or inquire your engineers. RAC-510/511PE Hardware manual HUNDURE...
  • Page 50: Chapter 7 Troubleshoot

    2. Make sure that the card swiped has access authorization and is a valid card. 3. Check whether the electronic lock is properly installed. 4. Login to command mode and check the unlock door time settings via command code RAC-510/511PE Hardware manual HUNDURE...
  • Page 51: Appendix

    Range: 1~60000(Unit is 0.01sec.) ◣ [MASTER]↵ [11]↵ [Detection Time]↵ Completed Door Sensor Detection ◣ :Cancel or 1~60000(Unit is 0.01 sec.) Time (Default=0) [MASTER]↵ [12]↵ [Unlock Door Duration]↵ Enable/Disable Conditional Unlock Door Completed ◣ :Disable,1~9999 sec Settings RAC-510/511PE Hardware manual HUNDURE...
  • Page 52 Access Granted for ◣ :No 1:Yes Master Code (Default is 0; means Access Denied ) Set Date [MASTER]↵ [25]↵ [yymmddww]↵ Completed ◣ :Year 00~63 (For RAC-510 only) :Month 01~12 ◣ :Date 01~31 ◣ :Weekday 01~07 ◣ RAC-510/511PE Hardware manual HUNDURE...
  • Page 53 ◣[+4] Enable anti,0:Disable Anti Select value only [+0] T1/T2 interface ◣ [+16] Wiegand 26 interface (8 Digits) ◣ ◣ 32] Wiegand 26 interface (10 Digits) ◣ 48] Wiegand 34 interface (10 Digits) [MASTER] ↵ [99] ↵[99]↵ Completed Initialize RAC-510/511PE Hardware manual HUNDURE...
  • Page 54: Appendix B:wiring Material Requirements

    Upgrade the cable specification as per environmental interference factors. It is recommended to use larger cable wires for future use. It is highly recommended to use shielded twisted pair wire for readers and communication cable to increase transmission distance and interference resistance ability. RAC-510/511PE Hardware manual HUNDURE...
  • Page 55 In no event shall manufacturer’s liability exceed the price paid for the product from direct, indirect, special, incidental, or consequential, damages resulting from the use of the product, its accompanying software, or it’s documentation. Hundure makes no warranty or representation expressed, implied, or statutory, with respect to its products, contents of use of this documentation and all accompanying software, and specially disclaims its quality, performance, merchantability or fitness for any particular purpose.

This manual is also suitable for: