Wiring Diagram - Daikin VRV RXYQ5P7W1B Technical Data Manual

Small footprint combination, r410a, air conditioning systems
Hide thumbs Also See for VRV RXYQ5P7W1B:
Table of Contents

Advertisement

7

Wiring diagram

7 - 1 Wiring diagram
RXYQ5P
Power supply
3/N ~ 400/230V 50Hz
Position of M1C, M1F
El. compo. box
M1C
Outer shell
A1P
Printed circuit board (Main)
A2P
Printed circuit board (Noise filter)
A3P
Printed circuit board (Inverter)
A4P
Printed circuit board (Fan)
A5P
Printed circuit board (ABC I/P)
BS1 ~ BS5
Push button switch (Mode, Set, Return, Test, Reset)
C1
Capacitor
C63, C66
Capacitor
DS1, DS2
Dip switch
E1HC
Crankcase heater
F1U
Fuse (250V, 8A,
) (A4P)
F1U, F2U
Fuse (250V, 3.15A,
) (A1P)
F5U
Field Fuse
F400U
Fuse (250V, 6.3A,
) (A2P)
H1P ~ H8P
Pilot lamp (Service monitor-orange)
[H2P] Prepare, test ......................... flickering
Malfuntion detection .... light up
HAP
Pilot lamp (Service monitor-green)
K1
Magnetic relay
K2
Magnetic contactor (M1C)
K3R
Magnetic relay (Y1S)
: Field wiring
: Indication of parts outside switchbox
: Terminal strip
: Connector
: Terminal
: Protective earth (screw)
NOTES
1
This wiring diagram applies only to the outdoor unit.
2
When using the option adaptor, refer to the installation manual.
3
Refer to the installation manual, for connection wiring to indoor-outdoor transmission F1 - F2, outdoor-outdoor transmission F1 - F2 and on how to use BS1~BS5 and DS1, DS2 switch.
4
Do not operate the unit by short-circuiting protection device S1PH.
®
• Outdoor Units • VRV
Heat Pump • RXYQ5-54P7W1B(A)
W
U
V
Detail of M1C
K4R
Magnetic relay (Y2S)
K5R
Magnetic relay (Y3S)
K7R
Magnetic relay (E1HC)
K11R
Magnetic relay (Y4S)
L1R
Reactor
M1C
Motor (Compressor)
M1F
Motor (Fan)
PS
Switching power supply (A1P, A3P)
Q1RP
Phase reversal detect circuit
Q1DI
Earth leakage breaker
R10
Resistor (Current sensor) (A4P)
R50, R59
Resistor
R95
Resistor (Current limiting)
R1T
Thermistor (Air) (A1P)
R1T
Thermistor (Fin) (A3P)
R2T
Thermistor (Suction)
R3T
Thermistor (M1C Discharge)
R4T
Thermistor (Heat exchanger deicer)
R5T
Thermistor (Liquid pipe)
R6T
Thermistor (Accumulator)
S1NPH
Pressure sensor (High)
COLORS : BLK : Black
BLU : Blue
BRN : Brown
GRN : Green
GRY : Grey
®
• VRV
Systems • Outdoor Units
5 HP
ON
ON
OFF
OFF
Cool/heat selector
In-Out
A
B
C
F1
F2
Cool
Heat
S2S
S1S
Cool
Heat
Fan
Indoor
(F1)(F2)
Cool/heat selector (option)
S1NPL
S1PH
SD1
V1R
V1R, V2R
X1A, X2A
X1M
X1M
X1M
Y1E
Y1S
Y2S
Y3S
Y4S
Z1C ~ Z5C
Z1F
Cool/heat selector
S1S
S2S
ORG : Orange
PNK : Pink
RED : Red
WHT : White
YLW : Yellow
(Note 2)
Out-Out
Out-Multi
F1
F2
Q1
Q2
Outdoor
(F1)(F2)
Front layer
Rear layer
Position in switch box
Pressure sensor (Low)
Pressure switch (High)
Safety devices input
Power module (A4P)
Power module (A3P)
Connector (M1F)
Terminal strip (Power supply)
Terminal strip (Control) (A1P)
Terminal strip (A5P)
Electronic expansion valve (Main)
Solenoid valve (Hot gas)
Solenoid valve (Oil return)
Solenoid valve (4 way valve)
Solenoid valve (Injection)
Noise filter (Ferrity core)
Noise filter (With surge absorber)
Selector switch (Fan/cool - heat)
Selector switch (Cool - heat)
2TW27236-1A
3
125