Bio Smart Technologies In-Wall Series Installation And Operator's Manual

Therapeutic infrared heating systems for a green, healthy environment

Advertisement

Quick Links

Therapeutic Infrared Heat
Installation and Operator's Manual
Therapeutic infrared heating systems
BioSmart
BioSmart
®
In-Wall Far Infrared Heaters.
.
B
S
I O
for a green, healthy environment
Technologies
Feel the Difference.
M A R T
In-Wall Series
Bio-1000F
Bio-1200F
Save these
Instructions
Includes:
Product information
Thermostat options
Installation guidelines
Operating Instructions
Technical Specifications
Warranty & Service instructions
.
®

Advertisement

Table of Contents
loading

Summary of Contents for Bio Smart Technologies In-Wall Series

  • Page 1 ® In-Wall Far Infrared Heaters. M A R T ® Therapeutic Infrared Heat Installation and Operator’s Manual Therapeutic infrared heating systems for a green, healthy environment In-Wall Series Bio-1000F Bio-1200F Save these Instructions Includes: Product information Thermostat options Installation guidelines...
  • Page 2: Table Of Contents

    Table of Contents Section 1 - Understanding BioSmart Infrared Technology Section 2 - Unpacking Section 3 - For your Safety / Warnings Section 4 - Installation Requirements Heater Location Thermostat Location and Requirements Thermostat Options Section 5 - Mounting Instructions New Construction Retrofit Installations Wiring Instructions...
  • Page 3: Section 1 - Understanding Biosmart Infrared Technology

    Page 1 Section 1 - Understanding BioSmart Infrared Technology Infrared technology is not new, however, the use of commercial infrared technology for zoned interior applications is relatively new. BioSmart Technologies was the first U.S. company to obtain a U.S. patent for modular infrared heating systems that utilize industrial grade ceramic plates.
  • Page 4: Section 2 - Unpacking

    Page 2 Section 2 - Unpacking It is important that you remove the packing materials and closely examine your unit before installing. Check to make sure that all the necessary installation hardware is included. Inspect the unit for any shipping damage that may have occurred. Once you have done this, it is best to review the first five (5) sections of this manual before proceeding to install the unit.
  • Page 5: Heater Location

    Page 3 Heater Location For best performance it is recommended that the air flow pattern in the room becomes circular. This is accomplished by mounting the heater to one side of the room, as per the illustration, in order to create a circular flow around the room. Where multiple units are installed in larger rooms, this circular pattern can be maintained by positioning the units to complement the air flows.
  • Page 6: Section 5 - Mounting Instructions

    Page 4 Section 5 - Mounting Instructions The BioSmart heater was designed for installation in a standard 2"×4" wall with either 1/2" or 5/8" sheetrock. There are two sets of mounting brackets: Retrofit Installation Bracket New Construction Bracket New Construction If the new construction brackets are to be used, the heater is installed before the sheetrock is applied to the wall.
  • Page 7: Wiring Instructions

    Page 5 Warning: The heater is always mounted with the heat vent on top and the cold air intake at the bottom. Never mount the heater up-side down. Warning: Do not mount the heater in a flat ceiling. The heater should be mounted at least twelve (12) inches above the floor but no higher than twelve (12) inches from the ceiling. If the ceiling pitch is greater than a 4/12 pitch, as is the case with cathedral ceilings, the BioSmart unit may be mounted anywhere in the celling but no higher than 36"...
  • Page 8: Troubleshooting

    Page 6 Troubleshooting It is recommended that step B should be performed by a knowledgeable service technician. Check the breaker in the fuse panel Check the thermostat batteries if so equipped Check the reset button on the front of the plastic cover and push to reset Remove the plastic front cover by removing the four screws and lifting up to disengage the top flange on the cover Remove the bottom fan baffle screws to expose the PC board and the solid state relay...
  • Page 9: Component Diagram

    Page 7 Component Diagram Component Listings Cover Right Insulation Plate Grill Electronics Mounting Plate Heat Chamber Assembly Bottom Cover Ceramic Element Fans Left Insulation Plate Intake Baffle Ceramic Terminal Block Fan Assembly Top Insulation Plate High Limit Cover Case High Limit Switch ©2017 BioSmart Technologies...
  • Page 10: Schematic

    Page 8 Schematic Ceramic Infrared Element High-Limit Switch Ceramic Infrared Element Ceramic Terminal Block Fans FAN 1 FAN 2 FAN 3 FAN 2 FAN 3 FAN 1 WALL THERMOSTAT Standard In-Wall 1000w 2017/5/8 Section 9 - Technical Specifications • Cabinet: All metal - 22 & 24 gauge with synthetic, paintable •...
  • Page 11: Section 10 - Warranty & Service Information

    WARRANTY & SERVICE • BioSmart warrants this product, to the original purchaser or gift recipient, to be free from defects in workmanship and materials under normal use and service for a period of one (1) year from date of purchase. During this period BioSmart shall supply at no cost, excluding shipping, to the original purchaser, replacement parts as required to maintain product in good working order.
  • Page 12 Warranty Registration No. Dealer/Installer Information BioSmart® Far Infrared Heaters Green Technology for a Modern World North American Distribution and Sales BioSmart Technologies d, Suite 1 18324 Cook Roa Yelm, Washington 98597 Customer/Warranty Service: 800-595-9605 www.BioSmartSolutions.com...

This manual is also suitable for:

Bio-1000fBio-1200f

Table of Contents