P0311
Rated Motor Speed
Nominal motor speed (rpm) from rating plate
0 - 40000 1/min
P0700
Selection of Command Source
(on / off / reverse)
1 = BOP
2 = Terminal / Digital Inputs (default)
Selection of Frequency Setpoint
P1000
1 = BOP
2 = Analogue Setpoint (default)
Min. Motor Frequency
P1080
Sets minimum motor frequency
(0 - 650 Hz) at which the motor will run
irrespective of the frequency setpoint. The value
set here is valid for both clockwise and anti-
clockwise rotation
Max. Motor Frequency
P1082
Sets maximum motor frequency (0 - 650 Hz) at
which the motor will run at irrespective of the
frequency setpoint. The value set here is valid
for both clockwise and anti-clockwise rotation.
If the maximum frequency set in P1082 is greater than
the default frequency, then the same value must be set
in P2000.
14
English
Deutsch
Motornenndrehzahl
Motornenndrehzahl (1/min) vom Typenschild
Wahl von Befehlsquellen
(EIN / AUS / Richtungsumkehr)
1 = BOP
2 = Klemmen (Werkseinstellung)
Wahl des Frequenzsollwerts
1 = BOP
2 = Analogsollwert (Werkseinstellung)
Minimal Motorfrequenz
Stellt die minimale Motorfrequenz
(0 - 650 Hz) ein, mit der der Motor unabhängig
vom Frequenzsollwert läuft. Der hier
eingestellte Wert gilt für beide Drehrichtungen
Maximal Motorfrequenz
Stellt die höchste Motorfrequenz (0 - 650 Hz)
ein, mit der der Motor unabhängig vom
Frequenzsollwert läuft. Der hier eingestellte
Wert gilt für beide Drehrichtungen.
Sollte die maximale Frequenz grösser als die der
Standardeinstellung sein (50Hz/60Hz), dann muss dieser
Wert auch im Parameter P2000 eingetragen werden.