FIGURE 32.
Selector Bail Removal
FIGURE 33.
Selector Bail Removal
PRINT MAGNET ASSEMBLY REMOVAL
1.
Disconnect the cycle-clutch trip link (#1, Figure 34).
2.
Remove the support leg in the lower left corner (#2,
Figure 34).
3.
Remove the four mounting screws (#3, Figure 34).
4.
Carefully remove the magnet assembly.
FIGURE 34.
Print Magnet Assembly Removal
LATCH PUSHER REMOVAL
*
1.
Remove the two screws (#1, Figure 35) that hold the con-
tact plate to the frame.
Remove the contact assembl y,
holding it to the front with a rubber band.
2.
Disconnect the pusher springs (#1, Figure 36).
3.
Remove the C-clip on the end of the shaft (#2, Figure
36) and remove the shaft unt i I the desi red pusher is free.
4.
The following adjustments should be checked after a
latch-pusher is replaced.
a.
Latch to pusher clearance
b.
Latch-pusher to armature clearance
*
Not present on all printers.
FIGURE 35.
Latch Pusher Removal