Maintenance - Neilsen CT1075 Original Instructions Manual

10mm air belt sander
Table of Contents

Advertisement

2. Loosening clamp bolt (fig.3.1. on the top of sander) allows the angle between the grip and
the belt to be altered to suit the job in hand. After adjustment retighten the clamp bolt.
3. Once connected to the air supply the sander is started by squeezing the trigger (2).
4. To remove and replace the sanding belt push the idle pulley (3) towards the drive pulley (4)
against spring pressure. The pulley bracket (5) will retract and lock allowing removal/fitting
of the belt. When the new belt is in position release the pulley bracket by pushing in and
holding the idle pulley, then press and hold the tension bar (6) whilst releasing the pressure
on the idle pulley.
5. The tracking of the belt can be altered by adjusted cross head screw (7).

MAINTENANCE

WARNING! Disconnect sander from air supply before changing accessories, servicing or
performing maintenance. Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
1. If the air supply system does not have an oiler lubricate the sander daily with a few drops of a
good grade air tool oil dripped into the air inlet (fig.3.8) before use.
2. Clean the sander after use and change belt when required.
3. Loss of power or erratic action may be due to the following:
a) Excessive drain on the air supply. Moisture or restriction in the air line. Incorrect size or
type of hose connectors. To remedy, check the air supply and follow instructions in
Section "PREPARING FOR USE".
b) Grit or gum deposits in the sander may also reduce performance. If your model has an air
filter (located in the area of the air inlet), remove the filter and clean it. Flush the sander out
with gum solvent oil or an equal mixture of SAE No.10 oil and kerosene. Allow to dry before
use.
If you continue to experience problems, contact your local service agent.
4. For a full service contact your local service agent.
5.When not in use, disconnect from air supply, clean and store in a safe, dry, childproof
location.