Nordmende CSG63LPGWH User Manual page 15

Free standing cooker
Table of Contents

Advertisement

Available languages

Available languages

Cut off the main gas supply and unplug
the appliance from the mains electrical
supply.
Remove the burner caps and the
adapters.
Use a 7 mm spanner to unscrew the
injectors.
Replace the injector with the ones from
the gas conversion kit, with the correct
diameters for the type of gas that is
going to be used, according to the gas
injector table.
Burner
cap
Adapter
Cup
Spanner
Adapter
Oven/Grill (if available) Injectors
The oven and grill injectors are held in
position by a single screw on the tip of the
burner.
For oven burners, open the drawer
compartment and locate the assembly
screw below the burner. Remove the screw,
move the burner diagonally and the injector
will be revealed on the rear side of the
burner box.
For grill burners, the screw is already
visible. Remove the screw, pull the grill
burner towards you and the injector will
be visible on the rear surface of the oven
cavity.
Oven burner
Injector
Remove the injectors using a 7mm
spanner and replace the injector with the
ones from the spare set. Make sure you
use corresponding diameters suitable to
the type of gas that is going to be used,
according to the information chart (which is
also supplied in the gas conversion kit).
Adjusting the minimum flame position
First of all, make sure that the appliance
is unplugged from the mains electrical
supply and that the gas feed is open.
The minimum flame position is adjusted
with a flat screw located on the valve. As
shown in the figures below; for valves with
a flame failure safety device, the screw is
located on the side of the valve spindle
and for valves without a flame failure
safety device, the screw is located inside
the valve spindle. To make adjusting the
flame position easier, we recommend that
you remove the control panel (and the
micro switch if your model has one) during
the alteration. The bypass screw must
be loosened for conversion from LPG to
natural gas. For conversion from natural
gas to LPG, the bypass screw must be
tightened.
Valve with flame failure
device
Bypass screw
EN - 15
Valve without flame
failure device
Screw(inside the hole)

Advertisement