The appliance should not be installed
next to a dishwasher, fridge, freezer,
washing machine or clothes dryer.
The appliance can be placed close to
other furniture on condition that in the
area where the
furniture's height does not exceed the
height of the cooktop.

2.2 Installation of the Cooker

If the kitchen furniture is higher than the
cooktop, the kitchen furniture must be
at least 10 cm away from the sides of
appliance for air circulation.
There should be a minimum 2cm blank
space around the appliance for air

2.3 Gas Connection

Assembly of gas supply and leakage
check
Connect the appliance in accordance
with applicable local and international
standards and regulations. First, check
what type of gas is installed on the cooker.
This information is available on a sticker
on the back of the cooker. You can find
the information related to appropriate gas
types and appropriate gas injectors in
the technical data table. Check that the
feeding gas pressure matches the values
on the technical data table, to be able to
get the most efficient use and to ensure the
minimum gas consumption. If the pressure
of used gas is different than the values
appliance
is set up, the
A
B C
circulation.
If a cooker hood or any cupboard is to
be installed above the appliance, the
safety distance between cooktop and
any cupboard/cooker hood should be as
shown below.
A (mm)
B (mm) Cooker Hood/Cupboard
C (mm)
D (mm)
E (mm)
C
E
D
stated or is not stable in your area, it may
be necessary to assemble an available
pressure regulator on the gas inlet. You
should contact an authorised service centre
to make these adjustments.
Points that must be checked during
flexible hose assembly
If the gas connection is made by a
flexible hose fixed onto the gas inlet of
the hob, it must be fixed on by a pipe
collar.
Connect your appliance with a short
and durable hose that is as close as
possible to the gas source.
The permitted maximum length of the
hose is 1.5 m.
EN - 13
420
650/700
20