Download Print this page

Max G Series Operational Manual page 9

Flow metering systems

Advertisement

Transmitter Specifications
Supply Voltage & Current
Analog Resolution
FREQUENCY MODEL SPECIFICATIONS
Output (5.0 Volt Supply)
Short Circuit Current (1)
Output Impedance
Rise/Fall Time
Output Update Rate(2)
Min/Max Frequency
Resolution
Ambient Temperature Range
Maximum Temp, Process Fluid
(30ºC Ambient, 5V supply)
Anti-dither Range Default
Signal Filtering
(1) Continuous Short Circuit is not recommended. The output current should not exceed 10 mA
(2) Events are seen as output transitions 1 ms after they occur
Frequency output
Analog output
Adjustable without recalibration to any range of
- or -
+/- 20mA - Models ending in "A0" and "B0"
+/- 10 Vdc - Models ending in "C0" and "D0")
No Load 0.00 / 4.80 Volts
2.5K Load to Common 0.00 / 4.60 Volts
2.5K Load to +5 Volts 0.25 / 4.80 Volts
45 mA
100 Ω
0.2 μ Sec
1 ms
0-60 kHz
1 - 1000 pulses/rev
Transmitter (Storage) –40ºC to 85ºC (–40ºF to 185ºF)
Transmitter (Operation) (3) –40ºC to 80ºC (–40ºF to 175ºF)
(Standard Model)
(High Temp Model)
(Ultra High Temp Model)
50% Revolution of Meter for unidirectional (software selectable
from 1 - 100% of 1 revolution). 2% for bi-directional meters
Software selectable from 1ms to 250ms time constant
5-26 Vdc @ 30 mA typical
12Vdc @ 90 mA typical
24Vdc @ 45 mA typical
FREQ OUTPUT
90ºC (195°F)
160ºC (320°F)
232ºC (450°F)
ANALOG OUTPUT
80ºC (175°F)
Not Available
200ºC (392°F)
9

Advertisement

loading

This manual is also suitable for: