No.
Cable
2
Smart Power
Sensor signal
cable
3
AC output
power cable
4
PE cable
The PE point at the AC output port is used only as a PE equipotential point, and cannot
substitute for the PE point on the enclosure.

5.2 Installing the PE Cable

Context
Do not connect the neutral wire to the enclosure as a PE cable. Otherwise, electric shocks
could occur.
Procedure
Step 1 Crimp the OT terminal.
Issue 01 (2018-08-30)
Type
Four-core outdoor shielded
twisted pair cable
Not using the PE
equipotential point at the
AC output port: two-core
(L and N) outdoor copper
cable
Using the PE
equipotential point at the
AC output port:
three-core (L, N, and PE)
outdoor copper cable
Single-core outdoor copper
cable with an M6 OT
terminal
Copyright © Huawei Technologies Co., Ltd.
Conductor
Cross-sectional
Area Range
2
0.25–1 mm
2
4–6 mm
2
4–10 mm
5 Electrical Connections
Outer
Source
Diameter
4–11 mm
Purchased by
the customer
10–21 mm
Purchased by
the customer
Purchased by
N/A
the customer
39