Summary 4.7 Reading of the configuration 1 . INTRODUCTION 4.8 Access code 2 . SPACE REQUIREMENTS 4.9 Programming of a new access code 4.10 Functions accessible in the main menu 3 . WIRING 4.10.1 - Simulation of the display 4 . PROGRAMMING 4.10.2 - Simulation of the analog output 4.1 Communication with the instrument 4.10.3 - Menu CLEAr :...
(specify on order) Insulated analog output : A The series Peca 5 offers you an extensive range of high accuracy program- Active or passive current, or voltage output. mable display centrals, IP 65 on front face. Each instrument is equipped Programmable scale ratio with enlarging effect.
2. SPACE REQUIREMENTS Case dimensions : (with terminals) 96 x 48 x 124 mm Mounting panel maximum thickness 30 Terminals External Case seal tightenings Panel mounting Cut out 44 x 91 mm Connectors plug-off connectors on Protection : rear face for screwed connections Front face : IP 65 (2.5mm², flexible or rigid) Case : IP20...
: A - inputs - do not connect too close : the input network and the Peca 5 power supply wires, - do not connect too close : the inut network and all the Peca 5 output wires, Location of terminals - use for all Peca 5 outputs shielded cables connected to the GND on both ends.
And choice of the decimal point by 4. PROGRAMMING Validate this choice by 4.1 Communication with the instrument And choice of the unit by Several functions can be accessed from the measuring : Functions Alarms Validate this choice by key Indication display 1 Led 1 Measure...
Page 7
Note : ⇒ Press to revert to menu ⇒ In mode programming, the instrument will automatically revert to measure with the previous configuration if no key is pressed during 1min. Move through menus / choice...
This will set the direction of the current (180° rotation in the 4 quadrant diagram). • Programming in mode receiver P displayed by the Peca 5 > 0 Q displayed by the Peca 5 > 0 Active energy counters P- Q+ P+ Q+ EA.in...
• Mathematical cosine : 4.5.8 Programming of the cosine the cosine sign will indicate the direction of the current (receiving or The cosine sign will indicate the direction of the current generating). MAtH (receiver or generator). Eg. : The load can be either current receiving or generating. A cosine The cosine sign will indicate the nature of the load between -0.5 and +0.5 is transmitted on a 4-20mA output.
When the cosine oscillates around -1/+1, the current output remains a) Mode alarm around 12mA. The unlinear transfer function does not allow the use of a digital panel meter on the current output. Choice of the operating mode : ModE.x •...
· On the relays : tiME.x • Time delay on the alarm No influence of a self-diagnosis error on the relay The relay time delay is adjustable from 000.0 to 025.0s. in 0.1s increases. It is active both on switching and switching back. Relay de-activated (coil not supplied) in case of self- diagnosis error t.Act.X...
nuLL • Deleting of the unsignificant zeros Sub-menu About Suppresses the unsignificant zeros on the left Validation / nuLL hand side from the display. Vertical move Eg. : Display value 0015 PECA5 Type of instrument Display 0015 nuLL 1 2 3 4 5. N°...
4.9 Programming of a new access code 4.10.2 Simulation of the analog output (Accessible according to the programmed P .CodE access code and with option analog output) If code not valid GEnE. (old) Enter pre- Display during 2s. vious code GEnE.
5.2 Functions which require pressing several keys : 5. FUNCTIONS ACCESSIBLE DIRECTLY FROM THE DISPLAY 5.2.1 Automatic setting of the cut off (Accessible according to the programmed access code) 5.1 Functions which require pressing only 1 key : Automatic setting of the voltage cut off a / Display of the min.
5.2.4 Visualisation and setting of the alarm setpoints 7. GENERAL WARRANTY TERMS Option 2 or 4 relays WARRANTY applying and duration Setting of the setpoints : There are 2 ways to adjust setpoints : This instrument is under garantee for a duration of 1 year against any - either in mode programming entering the correct safety access code design or manufacturing defects, under normal operating conditions.
Page 20
CALI Current caliber Cut.I Current cut off Caliber 1A Cut.U Voltage cut off Caliber 5A FiLt. Digital filtering Voltage caliber CALU No filtering Caliber 150V Filtering 1 Caliber 500V Filtering 2 Type of signal SiGnA. Analog output Sinusoidal signal Access to the voltage output programming sub-menu Out.U Deformed signal dEFOr.
Page 21
Safeties Choice of the operating type tYPEX Access to the safeties programming sub-menu SECU relay output in mode alarm ALArM rEL.X PuLSE pulse output State of relay X in case of self-diagnosis error PARA.x Choice of the param. assigned to relay output x No self-diagnosis associated with the relay (see chapter 4.4.6) Relay de-activated in case of self-diagnosis error...
Access to the internal features reading sub-menu About single phase voltage U line current IL1 or integer PECA5 Type of instrument : Peca 5 single phase current I Identification number A0006 frequency of the network integer power factor integer...
9.2 Table of addresses of the units and decimal points of Other addresses the measures Value of the analog output Format nbr of words Address Dec. points and units of the measures Format Address in µA (mA output) double integer decimal point (MSB) / unit (LSB) integer in mV (10V output)
Writing of N words : Function N°16 : • Response with a negative measure : (eg. : active power) measure Request pattern : CRC 16 Nbr of Nbr of Slave Function 1st word Value of the words word to bytes to CRC 16 byte 1 byte 2...
9.5 CRC16 calculation algorythm : FFFF → CRC CRC ⊕ BYTE→ CRC n = 0 shifting by 1 bit to the right of CRC carry CRC ⊕ poly → CRC n = n + 1 n > 7 next byte end of pattern Note 1 : ⊕...