Universal display and control units for pulse input signals (30 pages)
Summary of Contents for Motrona ZU 252
Page 1
– motion – interface info@motrona.com www.motrona.com ZU 252 Incremental Counter Module With Analogue Output and Serial Interface Counter suitable for quadrature signals (A/B, 90º) as well as single channel inputs Counting inputs selectable to TTL/ RS422 format or to HTL / 10-30 volts format ...
Page 2
Safety Instructions This manual is an essential part of the unit and contains important hints about function, correct handling and commissioning. Non-observance can result in damage to the unit or the machine or even in injury to persons using the equipment! ...
1. Compatibility Hint This product is a successor model of the thousandfold approved converter type ZU251. The new product is suitable for a 100% replacement of the previous model, however some differences must be observed with DIL switch settings and parameter settings. Some essential advantages of ZU252 compared to ZU251 are: ...
2. Introduction ZU 252 represents a small and low-cost, but highly performing converter for industrial applications, where incremental counting of positions or events must be converted to either analogue format or serial data. The unit has been designed as a compact module with 12 screw terminals and a 9-position SUB-D connector (female).
3. Applicable Encoders and Sensors The converter can accept the following impulse sources: The ZU252 converter can accept the following impulse sources: Quadrature encoders with HTL level output (10 – 30 V) and either PNP or NPN or Push- Pull or NAMUR characteristics, using A and B outputs wit 90°...
If applicable, the encoder can be supplied from the ZU252 converter. Where the encoder is already supplied from a remote source, we recommend fully differential operation, with no GND connection between encoder and converter (see figures a. and b.) TTL encoder ZU 252 converter Screen 11 (+5.5V) 12 (GND)
4.2. Incremental encoder HTL / 12-30V The encoder may be supplied from the same source as the converter, or from another source. HTL encoder +24V ZU 252 converter Screen 12 (GND) 4.3. Proximity switches, photocells etc. This connection is fully similar to a HTL incremental encoder. With single-channel operation, input B remains unconnected or can be used to select the output polarity.
PC, according to need. GND int. RS232 RS485 Sub-D-9 (female on unit site) RS232: Please connect only pins 2, 3 and 5 ! ZU 252 120 Ohms 120 Ohms 120 Ohms 120 Ohms RS485- Bus ZU 252...
5. DIL Switch Settings There is one 8-position switch located on the top side (DIL1), and another 8-position switch is located on the bottom side of the unit (DIL2). These switches provide major settings of the desired properties of the unit. Changes of switch settings will become active only after cycling the power supply of the unit! Positions 7 and 8 of switch DIL2 are for internal factory use only and must...
5.2. Impulse levels and symmetric / asymmetric input formats Positions 5 and 7 of DIL1 together with positions 3 to 6 of DIL2 allow setting of all imaginable combinations of levels and formats. All subsequent tables use the following definitions: „0“...
5.2.2. Settings for special applications Where you find that the standard settings shown before are not suitable for your application, please go through the following setting options and find out the input levels and characteristics you need. DIL1 DIL2 Characteristics of input A Characteristics of input B 5 6 7 3 4 5 6...
5.4. Selecting the RS232 or the RS485 serial interface Position 1 of switch DIL1 selects between the RS232 interface and the RS485 interface. All connection details have already been explained in section 4.6. DIL1 / 1 Serial Interface RS232 interface is active (RS485 is switched off) RS485 interface is active (RS232 is switched off) 5.5.
6. Setup Procedure For all basic applications you can use the Teach feature for commissioning of the unit. Extended functions need a PC for setup and are described under section 8. As a first step it is advisable to check the input pulses by means of the LED marked “Status”. Position 6 of DIL1 must be set to ON for this test.
6.1. Operation as single channel counter (without direction signal) or as positional counter (with direction signal) Settings: Make sure that the DIL switches are set according to the encoder in use, and that position 6 of switch DIL1 is OFF (Teach function active). ...
PC setup anyway, as shown later. ZU 252 uses the DRIVECOM communication protocol according to the ISO 1745 standard. Details about the protocol can be found in our document “SERPRO.doc”, available for download under www.motrona.com...
DIL switch setting. To do this, select „Comms“ from the menu bar. Ex factory, all motrona units use the following serial standard settings: Unit No. 11, Baud rate 9600, 1 start/ 7 data/ parity even/ 1 stop bit ...
9. Displays and Softkeys The edit window for all unit parameters can be found on the left side of the screen. The INPUTS field shows the softkeys to switch the control commands on or off. Display boxes in the RS column indicate when the corresponding command is set to ON by PC. Display boxes in the PI/O column indicate that the corresponding command is ON by external hardware.
10. Parameter Settings Parameter Description „Register :8“ Setting: Multiplier These operands allow to convert the result to the desired engineering Divisor units. Offset The conversion affects the numeric value for serial read out from register <:8> only, but not the scaling of the analogue output. With the settings Multiplier = 1,0000...
Page 21
Parameter Description Edge Mode: This setting, with use of quadrature A/B input, allows simple count (x1) or full quadrature count (x4), by either accepting rising edges from input A only, or all rising and falling edges from inputs A and B simple count (x1) quadrature count (x4) Input Filter...
Page 22
Parameter Description Analogue Setting Teach Minimum These settings define your minimum and maximum count for input A Teach Maximum (respectively A/B quadrature), where your analogue output moves from 0 V to 10 V. You can enter your minimum and maximum settings as follows: ...
Page 23
Parameter Description Serial Communication: Unit Especially with RS 485 applications it is necessary to attach a specific address to Number: each unit, since up to 32 units can be connected to the same bus. You can choose any address number between 11 and 99. Factory setting = 11 The address must not contain a “0“...
Page 24
Parameter Description Serial Timer: This register determines the cycle time in seconds for the cyclic transmission. E. g. with a setting of 0.100 the selected register value will be transmitted every 100 ms. The accuracy of the timer is +/-500 µs. Setting the register to 0 disables cyclic transmissions.
Page 25
Parameter Description Backup Setting: Backup A Upon power-down the unit saves the actual counter values to the registers Backup Rest A Backup A and Backup B. Backup B Since the counters use impulse scaling factors, there may be remainders Backup Rest B which need to be considered later for error-free continuation of the count.
11. Free Programmable Linearization This programmable feature allows the user to convert the linear counting process to a non- linear analogue output. There are 16 programmable interpolation points available, which can be set in any desired distance over the full conversion range. Between two coordinates, the unit uses linear interpolation.
Page 27
You can visualize your curve on the PC screen or by means of an external oscilloscope. For this, select TOOLS, then TEST and there „Analogue Voltage Function“. The unit will now simulate a repeating counting cycle over the full range and generate the analogue signal accordingly.
12. Monitor Functions The monitor function of the OS3.2 PC software allows to display some important data on the PC screen with a continuous refresh cycle. Select „Monitor“ from the „Tools“ menu to open the basic view of the monitor window. Click to “Define”...
Page 29
Click to the Status field, next to the desired register code (where you read ON or OFF). Now you can toggle this position between ON and OFF by touching any key. Set all of the register codes to ON which you afterwards would like to trace on the monitor. Switch all unused register codes to OFF.
SERPRO_2a.doc which is available for download from our homepage www.motrona.com To request for a data transmission you must send the following request string to the converter: EOT = control character (Hex 04)
14. Test Functions When you select TEST from the TOOLS menu, you are able to verify the following data, by clicking to the corresponding field: Actual counter values DIL switch settings Internal supply voltages Analogue output state ZU25201e_e.doc / Sep-13 Page 31 / 36...
16. Technical Specifications Power Supply : 18...30 VDC Power consumption : approx. 85 mA at 18 V approx. 60 mA at 30 V (+5.5V uncharged) Encoder supply : +5.5V +/- 5% (max. load: 250mA) Inputs (RS422/TTL differential) : RS422 compatible (differential level min. 1 V) or TTL differential, f = 1 MHz Inputs TTL single-ended...