schmersal ZQ 700-11 Operating Instructions Manual

schmersal ZQ 700-11 Operating Instructions Manual

Pull-wire emergency-stop switches

Advertisement

Quick Links

Operating instructions
Pull-wire emergency-stop switches
Operating instructions. . . . . . . . . . . . .pages 1 to 6
EN
Translation of the original operating instructions
Content
1
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.3 Mounting set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version
in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machinery or plant.
The safety switchgear must be exclusively used in accordance with the
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be
found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is provi-
ded without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded.
EN
ZQ 700
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZQ 700-11 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal ZQ 700-11

  • Page 1 2.3 Destination and use ........2 Further technical information can be found in the Schmersal 2.4 Technical data .
  • Page 2 Operating instructions Pull-wire emergency-stop switches ZQ 700 1.7 Exclusion of liability 2.4 Technical data We shall accept no liability for damages and malfunctions resulting from Standards: IEC/EN 60947-5-1, IEC/EN 60947-5-5, defective mounting or failure to comply with this operating instructions EN ISO 13850, NBR 13930 manual.
  • Page 3 B Reset button time during fitting, we recommend using the wire rope and 40,5 the combined fixing and tensioning system from Schmersal. Alternatively, wire thimbles and wire clamps can be used in 3.3 Mounting set-up conjunction with a tensioner. In this case, the red PVC sheet...
  • Page 4 Operating instructions Pull-wire emergency-stop switches ZQ 700 5. Set-up and maintenance 6. Disassembly and disposal 5.1 Functional testing 6.1 Disassembly The safety function of the safety components must be tested. The The safety switchgear must be disassembled in a de-energised following conditions must be previously checked and met: condition only.
  • Page 5: Ec Declaration Of Conformity

    Möddinghofe 30 42279 Wuppertal Place and date of issue: Boituva, November 22, 2013 Authorised signature Marco Antonio De Dato Head of Engineering and Design The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
  • Page 6 Production site: K. A. Schmersal GmbH & Co. KG ACE Schmersal Industrielle Sicherheitsschaltsysteme Eletroeletrônica Industrial Ltda. Möddinghofe 30, D - 42279 Wuppertal Rodovia Boituva-Porto Feliz, Km 12 Postfach 24 02 63, D - 42232 Wuppertal Jardim Esplanada – CEP: 18550-000, Boituva – SP...

This manual is also suitable for:

Zq 700-02

Table of Contents