schmersal ZF 232 Series Operating Instructions Manual

schmersal ZF 232 Series Operating Instructions Manual

Foot switch

Advertisement

Quick Links

Operating instructions
Foot switch
Operating instructions . . . . . . . . . . . .pages 1 to 6
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the foot switch. The operating instructions
must be available in a legible condition and a complete version in the
vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards to
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The product must be exclusively used in accordance with the versions
listed below or for the applications authorised by the manufacturer.
Detailed information regarding the range of applications can be found in
the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all
prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is pro-
vided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of inadequate or improper use or manipulations of
the foot switch, personal hazards or damage to machinery or
plant components cannot be excluded. The relevant require-
ments of the standard ISO 14119 must be observed.
EN
F. 232
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZF 232 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal ZF 232 Series

  • Page 1: Table Of Contents

    1.7 Exclusion of liability ........2 Further technical information can be found in the Schmersal...
  • Page 2: Exclusion Of Liability

    Operating instructions Foot switch F. 232 1.7 Exclusion of liability Staggered operating principle (ordering suffix -HD) We shall accept no liability for damages and malfunctions resulting from The staggering is realised by means of a pressure point, which is defective mounting or failure to comply with this operating instructions installed under the pedal.
  • Page 3: Technical Data

    Operating instructions Foot switch F. 232 4. Electrical connection 2.4 Technical data Standards: IEC 60947-5-1, UL 508 Enclosure/cap/cover: Aluminium die-cast, powder-coated 4.1 General information for electrical connection Pedal: glass-fibre reinforced thermoplastic Cable entry: 1-pedal: 1 x M20 The electrical connection may only be carried out by 2-pedal: 2 x M25 authorised personnel in a de-energised condition.
  • Page 4: Set-Up And Maintenance

    Operating instructions Foot switch F. 232 5. Set-up and maintenance with 2 foot pedals 5.1 Functional testing The function of the component must be tested. The following conditions must be previously checked and met: 1. Check the integrity of the cable entry and connections T2F 232-11/11;...
  • Page 5: Eu Declaration Of Conformity

    Person authorized for the compilation Oliver Wacker of the technical documentation: Möddinghofe 30 42279 Wuppertal Place and date of issue: Shanghai, July 3, 2019 Authorised signature Uwe Seeger Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net.
  • Page 6 Production site: SCHMERSAL K.A. Schmersal GmbH & Co. KG Industrial Switchgear (Shanghai) Co., Ltd. 施迈赛工业开关制造(上海)有限公司 Möddinghofe 30, D - 42279 Wuppertal Cao Ying Road 3336 地址:上海市青浦区漕盈路3336号 Postfach 24 02 63, D - 42232 Wuppertal 201712 Shanghai / Qingpu, P.R.CHINA 邮编:201712...

This manual is also suitable for:

Tf 232 seriesTf 232-11Tfh 232-11Zf 232-11Zfh 232-11Tf 232-02 ... Show all

Table of Contents