Introduction; General; Intended Use - Honeywell F-BO-AFE70 Series Installation, Connection, Commissioning, Maintenance

Automatic purging units for aspirating detectors
Table of Contents

Advertisement

User Manual Series F-BO-AFE70
1

Introduction

1.1

General

This User Manual of the Automatic Purging Units F-BO-AFE70 provides the expert installer with
the information necessary for planning, configuration, installation, connection, parameterisation,
commissioning and maintenance of the Automatic Purging Units Series F-BO-AFE70.
The manner of operation of Purging units in general and of the Automatic Purging Units
F-BO-AFE70 in particular are described from page 10 onwards in Chapter 2: „Manner of opera-
tion of a Purging unit".
Fig. 1:
View of the Automatic Purging Unit F-BO-AFE70
Left:
Centre:
Right:
The following types of the Automatic Purging Units F-BO-AFE70 are available:
Type
F-BO-AFE70-2
F-BO-AFE70-3
1) IP54 means: protected against dust in harmful quantities, complete protection against contact,
protection against water splashed from all directions
2) DF ... refrigeration area down to -20°C
Table 1:
Type code of the Automatic Purging Units Series F-BO-AFE70
The Automatic Purging Units F-BO-AFE70-2 and F-BO-AFE70-3 have outer dimensions and func-
tionality in common, they essentially differ in the built-in solenoid valves which allow different air
flow rates and/or extended operating temperatures. The Automatic Purging Unit F-BO-AFE70-2
with a typical air flow rate of the solenoid valve of approx. 3,500 l/min (ANR) at 0.7MPa (7bar) is
designed both for small as well as for larger pipe systems with a large number of aspiration holes.
Thanks to the solenoid valve's typical air flow rate of approx. 5,000 l/min (ANR) at 0.7MPa (7bar),
the Automatic Purging Unit F-BO-AFE70-3 is suitable for even larger and further-flung pipe sys-
tems, and in addition it allows use in environments with low temperatures (down to -20°C). Notes
with regard to dimensioning can be found from page 14 onwards in Chapter 4: „Pneumatic com-
ponents – dimensioning". The functions of the Purging units are described starting on page 10 in
Chapter 2: „Manner of operation of a Purging unit".
The information in this User Manual relates to the firmware release number PL0200_V_1.00 of the
control board. In Fig. 11 the position of the label is indicated where the version of the firmware
used can be read. Devices using firmware with another release number can differ in their function
from the range of functions described in this document.
1.2

Intended use

The Automatic Purging Units F-BO-AFE70 are designed and intended exclusively for purging
pipes of aspirating smoke detectors for fire detection systems in buildings, within the limits
described in this User Manual. Any other use of the devices is expressly not intended and forbid-
den.
I56-4252-010
D200-104-00
Automatic Purging Unit F-BO-AFE70-3 without cover
Automatic Purging Unit F-BO-AFE70-3 view of the solenoid valve
Automatic Purging Unit F-BO-AFE70-3 with cover
Name
Automatic Purging Unit/3500L/IP54
Automatic Purging
Unit/5000L/DF/IP54
Chapter 1 • Introduction
Art. No.
1)
F-BO-AFE70-2
F-BO-AFE70-3
1) 2)
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-bo-afe70-3F-bo-afe70-2

Table of Contents