6.1 Calibration (Ounce Method)

If you do not wish to use the calibration kit method, the following
method may be used. All you need is a tape measure, stop watch and
a container that accurately measures U.S. fluid ounces.
1. Fill the sprayer tank approximately half full with clean water.
2. Set up two stakes, 204 ft. apart in actual spraying conditions.
3. While driving at spraying speed, note the length of time required to
drive 204 ft. Repeat several times and take the average of the times
recorded.
4. With the sprayer operating at intended spraying pressure, collect the
output from one nozzle for the length of time determined in step 3.
The number of U.S. fluid ounces will exactly measure the application
rate.
e.g. 15 U.S. fluid ounces = 15 U.S. gallons per acre
NOTE: This method only works if the nozzle spacing is 20".
For conversion to Imperial gallons per acre, multiply U.S. GPA x .833
For conversion to liters per hectare, multiply U.S. GPA x 9.34
For conversion to liters per acre, multiply U.S. GPA x 3.78

7.0 MAINTENANCE

WARNING: UNCLEAN SPRAYERS CAN BE HAZARDOUS TO
PEOPLE AND ANIMALS. NEVER LEAVE A SPRAYER CONTAIN-
ING CHEMICALS WHERE IT COULD BE ACCESSED BY UNAU-
THORIZED PEOPLE OR ANIMALS.
IMPORTANT: Always clean the boom at the end of your workday or
before servicing to avoid unnecessary contact with chemicals.
In order to derive full benefit from the sprayer for many years, the
following few, but important rules should be followed.

7.1 Cleaning The Sprayer

Read the entire label of the chemical used. Take note of any particular
instructions regarding recommended protective clothing, deactivating
agents, etc. Read the detergent and deactivating agent labels. If
cleaning procedures are given, follow them closely.
®