Trane 4TVS0007DF000A Technical & Service Manual page 6

Tvr lx systems. floor standing indoor unit with dc fan motor 220-240v/50-60hz/1ph
Table of Contents

Advertisement

Model
Power supply
Capacity
Cooling
Input
Rated current
Capacity
Heating
Input
Rated current
Model
Type
Indoor
Brand
fan
Input
motor
Output
Speed (h/m/l)
Number of rows
Tube pitch(a)* row pitch(b)
Fin spacing
Indoor
Fin type
coil
Tube outside diameter and type
Coil length*height*width
Number of circuits
Indoor air flow (H/M/L)
Indoor noise level (H/M/L)
Dimension (W*H*D)
Indoor
Packing (W*H*D)
unit
Net/Gross weight
Refrigerant type
Throttle
Design pressure
Refrigerant piping
Liquid side/ Gas
Power wiring
Connecting wiring
Signal wiring
Drainage water pipe diameter
Notes: 1.Nominal cooling capacities are based on the following conditions: return air temperature : 27°CDB, 19°CWB, outdoor
temperature:35°CDB,equivalent ref. Piping: 8m(horizontal)
2.Nominal heating capacities are based on the following conditions: return air temperature: 20°CDB,outdoor
temperature: 7°CDB,6°CWB,equivalent ref. Piping: 8m(horizontal)
3.Specifications of F3 series are measured at 10Pa external static pressure.
4TVS0024DF000AA
V-
kW
7.1
W
62
A
0.56
kW
8.0
W
65
A
0.56
WZDK100-38GS-3
Panasonic/Welling/Shibaura
90
W
72
W
1140/1040/910
r/min
2
25.4*22
mm
1.8
mm
mm
1068*254*44
mm
4
1380/1100/870
m3/h
44/39/33
dB(A)
1340*545*212
mm
1425*639*305
mm
kg
32/38
Type
Model
MPa
Ф9.53/Ф16
mm
2
mm
2
mm
mm
Floor standing indoor unit with DC fan motor
4TVS0027DF000AA
220-240V, 1Ph, 50/60Hz
WZDK100-38GS-3
DC motor
Panasonic/Welling/Shibaura
1140/1040/910
Hydrophilic aluminum
Φ9.52 inner grooved tube
1068*254*66
1380/1100/870
1340*545*212
1425*639*305
R410A
EXV (Built-in)
D20MISZ-1R(L)
4.4/2.6
Ф9.53/Ф16
3*2.5(L≤20m); 3*3.5(L≤50m)
3*0.75
ODФ25
8.0
62
0.59
9.0
63
0.59
86
69
3
25.4*22
1.8
3
44/39/33
35/39
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents