2. Suction Filling Device (if fitted)
WARNING! Avoid contamination or personal
injury. Do not open suction valve towards
Suction Filling Device unless pump is run-
ning and filling hose is connected. If this valve is
opened without pump running, liquid will stream out
of the MANIFOLD.
The Suction Filling Device is operated as follows:
T041-0013
1. Remove cover A, and connect suction hose B to
Suction Manifold.
2. Engage diaphragm pump and set P.T.O. revolutions at
540 r/min or 1000 r/min (depending on pump model)
3. Turn handle on Suction Manifold towards Filling
Device.
Black
Green
4. The tank is now filled with water. Keep an eye on the
liquid level indicator.
5. Turn handle on Suction Manifold away from Filling
Device to discontinue filling process. Then disengage
pump.
6. Disconnect suction tube B and replace cover.
NOTE! Observe local legislation regarding use of Filling
Device. In some areas it is prohibited to fill from open
water reservoirs (lakes, rivers etc.). It is recommended
34
Operation
A
B
Green
Green
T020-0003
only to fill from closed reservoirs (mobile water tanks
etc.) to avoid contamination.
WARNING! If suction hose/filter is carried on the
sprayer during spraying, it can be contaminated
by spray drift which will be transferred to lake/
river when filling!
3. Fast Filling Device (if fitted)
The Fast Filling Device is operated as follows:
1. Ensure spray liquid tank contains at least 50 litres of
water.
2. Remove cover (A) and
connect suction hose (B).
3. Turn handle on Pressure
Manifold towards Fast
Filler. With the P.T.O. at
540 r/min or 1000 r/min
(depending on pump
model), the pressure
gauge should indicate
about 10 bar.
4. If water is not seen in the
transfer tube, prime by
turning valve (C).
5. Keep an eye on the liquid
level indicator.
6. Turn handle on Pressure
Manifold away from Fast
Filler to discontinue filling
process.
NOTE: Turn handle towards
-operating unit before turning away from Fast Filler in
order to avoid peak pressure blowing the safety valve!
Black
Green
7. Disconnect suction tube (B) and replace cover.
GB 08 04
T041-0002
C
B
A
Green
Green
T020-0005

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents