Power Testing; Short Circuit Testing - Changan M201 2014 Wiring Diagram

Table of Contents

Advertisement

1.1.3-3
1
When testing the voltage with test lamp
or voltmeter, connect the negative of
testing tools to battery negative.
2
Connect the other wiring harness of the
test lamp or the positive probe of the
voltmeter to the test position.
3
If a voltmeter is used and voltage display
lower 1 V above compared to the rated
value, it means a circuit fault. It means a
circuit fault if a test lamp is used and lamp
is not lit.

2. Power Testing

M1103005
1
Disconnect the negative battery cable.
2
Connect one wiring harness of the self-
powered test lamp or the probe of the
ohmmeter to the test component. If using
ohmmeter,
please
probes each other and use reset button
to adjust the ohmmeter to zero.
3
Connect the other wiring harness of the
test lamp or probe of the ohmmeter to the
other side of the test load.
4
If the bulb is lit, it means the circuit is
normal. If an ohmmeter is used and the
resistance value is very low or close to 0
Ω, it means the component has good
continuity.
Circuit Fault Diagnosis
Switch
connect
the

3. Short Circuit Testing

+B
2 E00
Switch
1 E00
1 C00
Solenoid
M1103006
1
Disconnect negative battery cable.
2
Connect one wiring harness of the self-
powered test lamp or one probe of the
ohmmeter to the output terminal of the
fuse.
3
Connect the other wiring harness of the
test lamp or other probe of the ohmmeter
to the grounding.
two
4
Disconnect all the electrical loads to the
fuse.
CAUTION: If not disconnecting all the
electrical loads to the fuse, when testing
the low resistance circuit like lights, the
ohmmeter will always display the low
value. This will cause wrong judgement.
5
Do the careful inspection from the place
closest to the fuse.
6
If the bulb is lit or ohmmeter has value
display less than 5 Ω, it means the short
circuit to the ground.
Voltmeter
I/P Fuse and
Relay Box
Test Lamp
M201 2014.01
1.1.3-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents