4. Fill with good quality jack oil. We recommend Mobil DTE 13 or
equivalent.
Lubrication
 A coating of light lubricating oil to pivot points and hinges will help to
prevent rust and assure that pump assemblies move freely.
 Periodically check the pump piston and ram for signs of rust or
corrosion. Clean as needed and wipe with an oily cloth.
SYMPTOM
Jack will not lift load
Jack will lift, but not
maintain pressure
Jack will not lower after
unloading
Poor lift performance
Will not lift to full extension

Troubleshooting

POSSIBLE CAUSES
Release valve not tightly
closed
Overload condition
Hydraulic unit malfunction
Release valve not tightly
closed
Overload condition
Hydraulic unit malfunction
Reservoir overfilled
Linkages binding
Fluid level low
Air trapped in system
Fluid level low

Safety Precautions

NEVER ride bike up onto lift.
DO NOT raise Lift with bike untied.
Do not hold onto lift while raising and lowering.
Do not raise or lower lift using your own strength.
DO NOT put any body parts within the interior frame of the lift
while raising or lowering.
- 22 -
www.KendonUSA.com
CORRECTIVE ACTION
Ensure release valve tightly
closed
Remedy overload condition
Ensure adequate air supply
Ensure release valve tightly
closed
Remedy overload condition
Contact Kendon for Service
Drain fluid to proper level
Clean and lubricate moving
parts
Ensure proper fluid level
With ram fully retracted,
remove oil filler plug to let
pressurized air escape,
then reinstall oil filler plug
Ensure proper fluid level