PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS PRODUCT USE DESCRIPTION The Clodagh Libra is a powered positioning table used to support the client during spa treatment, mas- sage, pedicure and manicure procedures. It is intended to be operated by a healthcare professional in a spa environment.
Page 5
3. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Contact Oakworks Customer Service before use. 4. Keep the cord away from heated surfaces.
INSTALLATION The table comes completely assembled and ready to use. Plug the cord into a functioning GFCI outlet that is rated for the table. Arrange the power cord and foot switch so that they will not create a tripping hazard. Place the controls in a safe location where they are convenient and accessible.
Page 8
INSTALLATION c. The table comes equipped with a faucet that has flexible 3/8” compression lines with female ends. The customer supplied flexible line will need to have male 3/8” compression to be connected to the faucet supply line. Male/Female fitting connection Table - Female 3/8”...
INSTALLATION FACILITY ELECTRICAL INSTRUCTIONS When installed in the United States, the electrical wiring of this table must meet the require- CAUTION ments of the National Electric Code (NEC) and any applicable state or local codes. The elec- trical circuit providing 115V/15A power (230V overseas) to this table must be protected by a GFCI (ground fault interrupter circuit) installed by a qualified electrician.
DIRECTIONS FOR USE CONTROL OPERATIONS The Foot Control and Optional Hand Control operate all functions of the table with the touch of a button. Follow the directions below to access these functions. Seat Back Back Height up rest Back rest down Height down Seat forward...
DIRECTIONS FOR USE MOVING THE TABLE Before moving the table, disconnect the power cord from the power outlet. The table CAUTION weighs as much as 342 lbs. (155 kg.) Never lift the table by grasping the table top. You could damage the table and the electronics that run the tabletop. Four people are required to move the table safely.
DIRECTIONS FOR USE STORAGE SHELF USE CAUTION Maximum Shelf load weight: 225 lbs. (102 kg.) The table has a fully integrated wood shelf. The large under-table shelf provides storage for stacks of towels and other equipment without interfering with the lift capacity of the table. ACCESSORY OUTLET This product is equipped with an interior accessory outlet under the back rest section and attach to the frame.
DIRECTIONS FOR USE ADJUSTABLE ARM REST INSTALLATION AND ADJUSTMENT Do not use the arm rest for patient support during the mounting or dismounting of the chair. CAUTION The arm rest is not designed to support the patient’s weight. TO INSTALL THE ARM RESTS: The Arm Rests adjust automatically as the back rest moves to remain parallel to the floor.
DIRECTIONS FOR USE LEG REST USE CAUTION Maximum Leg Rest load weight: 125 lbs. (57 kg.) OPENING THE LEG REST CLOSING THE LEG REST 1. With both hands, gently lift the leg rest slightly 1. With both hands, gently lift the leg rest and push and pull outward until it stops.
DIRECTIONS FOR USE QUICKLOCK FACE REST * U.S. Patent #5,177,823 Do not put excessive weight or pressure on the Quicklock Face Rest. Do not extend the CAUTION dowels of the Quicklock Face Rest 3” (7.6 cm.) from the Fowler (Backrest) section. Double articulating action provides nearly limitless positioning options with the QuickLock Face ™...
DIRECTIONS FOR USE FOOT BATH USE CAUTION Risk of accidental injury. Exercise care when entering or exiting of the foot bath. Invalid or disabled persons should not use the hydro foot bath without trained supervision. Risk of scalding: Water tem- peratures in excess of 104º...
Page 17
DIRECTIONS FOR USE CLEANING THE FOOT BATH To maintain your pedicure sink and its pipeless jets at maximum level of hygiene, thoroughly clean the tub shell and jets after each use with a nonabrasive antibacterial cleaner, rinse thoroughly and dry completely. NEVER use abrasive cleaners on any part of the appliance. Disassembly &...
To reduce the risk of electric shock: DANGER - Always unplug this furnishing from the electrical outlet before cleaning. The following cleaners were tested by OAKWORKS ® and found to be acceptably compatible with all materials used in construction of our tables: Formula 409 ®...
- Always unplug this furnishing form the electrical outlet before cleaning. ® Follow the cleaners/disinfectant manufacturers’ directions for use. Please note that cleaning and disinfecting an OAKWORKS table is a two part process. First it must be cleaned of any visible soil, then it can be disinfected. The table should be cleaned as soon as possible after use.
L A P S E B 3 1 2 5 7 7 A C T T Z Z P B X X Options Plumbing PB=Plumbed Foot Bath NP=Not Plumbed Foot Bath Spaces not used Fabric: TerraTouch Padding: 4” Aerocell Table Top Length Minimum Table Height Table Width Top - 4 Section Base Clodagh Libra...
™ CONTACT INFORMATION: Inc. ® AKWORKS 923 East Wellspring Road New Freedom, PA 17349 Phone: 717-235-6807 FAX: 717-235-6798 www.oakworks.com Part No.: MMMNST0020-EN Revision: 3 Revision Date: 03/06/2019 made in the USA with US & imported parts English, Printed in USA...