OAKWORKS Clodagh Libra Instruction Manual

Hide thumbs Also See for Clodagh Libra:

Advertisement

Quick Links

Libra
I N S T R U C T I O N M A N U A L
www.oakworks.com · 717.235.6807

Advertisement

Table of Contents
loading

Summary of Contents for OAKWORKS Clodagh Libra

  • Page 1 Libra I N S T R U C T I O N M A N U A L ™ www.oakworks.com · 717.235.6807...
  • Page 2 The information contained in this document is Printed in U.S.A. subject to change without notice and should not be construed as a commitment by Oakworks®, Inc. All rights are reserved. No Oakworks®, Inc. assumes no responsibility for part of this document may be...
  • Page 3: Table Of Contents

    TAbLe Of CONTeNTS table of contents Symbol Identification .................... pg 2 Warnings & Safety Instructions ................pg 3 Grounding Instructions ..................pg 6 Product Description & Table Specs ..............pg 7 Installation & Leveling Instructions ..............pg 8 Directions for Use Adjusting Height................
  • Page 4: Symbol Identification

    SyMbOL IDeNTIfICATION symbol IdentIfIcatIon This symbol, when used in this manual and on product labels, represents a caution. Be sure to read and comply with all precautions and warnings. This symbol, when used in documentation on this product, indicates danger and warns against an electrical shock hazard.
  • Page 5: Warnings & Safety Instructions

    WARNINGS & SAfeTy INSTRUCTIONS read and save these Important warnIngs & safety InstructIons InstructIons Improper use of this device can cause injury. Be sure to read all operating instructions prior to use to prevent injury to operator or client. Electrical Shock Hazard. •...
  • Page 6 WARNINGS & SAfeTy INSTRUCTIONS read and save these InstructIons Important warnIngs & safety InstructIons warnIngs • This product is equipped with an interior accessory outlet (110V only). The total electrical load plugged into this set of outlets is not to exceed contInued 1000 watts.
  • Page 7 WARNINGS & SAfeTy INSTRUCTIONS read and save these warnIngs InstructIons warnIngs & safety InstructIons • Be certain that the table is completely lowered prior to cautIons discharging an ambulatory patient. The patient may lose balance and fall. Do not leave clients unattended when table is set at its highest level.
  • Page 8: Grounding Instructions

    WARNINGS & SAfeTy INSTRUCTIONS (CONTINUeD) GROUNDING INSTRUCTIONS groundIng ground fault & groundIng InstructIons InstructIons cautIons • The integral GFCI should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button.
  • Page 9: Product Description & Table Specs

    PRODUCT DeSCRIPTION product descrIptIon backrest top Manicure Arm rests (2) Powder Coated Pedibath Steel base Hydraulic Lift Columns (4) Storage shelf table specIfIcatIons • Lift Capacity: 500 lbs. (226 kg.) • Weight: 200 lbs. (91 kg.) • Shipping Weight: 250 lbs. (114 kg.) • Shipping Box Dimensions: 81” L x 37” W x 31” H • Height Range: 25” - 33” (64-84 cm) • Width: 30” (76 cm) • Length: 77” (195 cm) • Top:...
  • Page 10: Installation & Leveling Instructions

    INSTALLATION assembly & InstallatIon InstallatIon InstallatIon The table comes completely assembled and ready to use. Plug the cord into a functioning GFCI outlet that is rated for the table. When operating the table’s controls be sure to observe Arrange the power cord and foot switch so that they will not create a tripping all cautions and warnings hazard.
  • Page 11: Directions For Use

    DIReCTIONS fOR USe adjustIng heIght of the table dIrectIons for use The table comes complete with a multi-functional hand control that operates the back- rest and seat positioning functions as well as a foot control that operates the height cautIon with ease.
  • Page 12: Adjusting The Top

    DIReCTIONS fOR USe adjustIng the top Hand Control - 4 Positioning Buttons The hand control operates all the positioning of the backrest and seat. Press and hold the appropriate button until the position desired is achieved and then release. When operating the table’s The arm rests will adjust automatically to provide the most in comfort and ergo- controls be sure to observe nomics while staying parallel to the floor, no matter what the position.
  • Page 13: Important Safety Note

    DIReCTIONS fOR USe Important safety note read and save these The cabinet hood area under the backrest top is not designed for stor- age or as an area to hold accessories while with a client. DO NOT use InstructIons this area for holding anything. Damage can occur to the table, especially when commands that are accessed by the hand control are activated.
  • Page 14: Side Armrests

    DIReCTIONS fOR USe sIde armrests: Though the arm rests adjust automatically to remain parallel to the floor in any position, there will still be times when you will need to move an arm rest out of the way or remove them altogether. We cautIon recommend that you move the arm rest out of the way to allow a client to get on or off the table.
  • Page 15 DIReCTIONS fOR USe dIrectIons for use sIde arm rests: c o n t To remove one or both arm rests just take hold of the base of the arm cautIon rest at the metal frame and somewhere on the cushion. Holding securely, rotate the arm rest while at the same time pulling slightly away from Do not sit on the Arm Rests.
  • Page 16: Quicklock Face Rest

    DIReCTIONS fOR USe QuIcklock™ face rest & head rest dIrectIons for use QuIcklock™ face rest: Be sure to use either the face rest or head rest for all treatments that require your client be sure to read all to lay flat. Double articulating action provides nearly limitless positioning options with cautions, warnings the QuickLock™...
  • Page 17: Foot Bath

    DIReCTIONS fOR USe openIng/closIng the foot sectIon dIrectIons for use To open fooT secTion Standing at the side of the table, with both hands, gently lift the moveable leg rest be sure to read all slightly and pull outward until it stops. cautions, warnings and instructions given Lower leg rest until it stops in a vertical position aside the foot bath...
  • Page 18: Foot Rest

    DIReCTIONS fOR USe QuIcklock™ face rest & head rest foot rest A foot rest is included with this product. It is designed to store under the foot end of the sink as shown. use these slots when using foot rest use these slots for foot rest...
  • Page 19: Moving Your Table

    DIReCTIONS fOR USe movIng the table dIrectIons for use cautIon Grasp at base corner Grasp The table weighs as much at base as 200 lbs. Do Not lift or corner move the unit without using at low height range proper safety procedures or equipment.
  • Page 20: Care & Cleaning

    CARe & CLeANING how to care for your table care & cleanIng In order to maintain the quality and ensure the life of the table, here are • Upholstery some preventative steps that can be taken to protect the upholstery on the chair and accessories.
  • Page 21: How To Clean The Foot Bath

    CARe & CLeANING how to clean the foot bath To maintain your pedicure sink and its pipeless jets at maximum level of hygiene, thoroughly clean the tub shell and jets after each use with a nonabrasive antibacte- rial cleaner, rinse thoroughly and dry completely. NEVER use abrasive cleaners on any part of the appliance.
  • Page 22: Power Lead Plugs

    CARe & CLeANING product power lead plugs IdentIfIcatIon power lead plugs IMPORTANT Part #: voltage (AC) Power Cord Plug akwork 7791 120v 60 Hz 3 prong grounded these parts are for North America identification only; they are not field serviceable items. 7791-03 220v 50 Hz Continental Plug;...
  • Page 23: Electrical Specifications

    Temperature: 32º - 100º F 0º-38º C Humidity: 60% relative humidity Pressure: no limitations known Storage & Transport During transport, DO NOT stack containers. warranty For full warranty details, please visit www.oakworks.com All warranties are limited to factory-provided replacement parts, factory repair or replacement, at the discretion of O ® akworks All warranties exclude damage caused by improper set-up, accident, abuse, misuse, neglect, use for other than intended purpose or reasonable wear such as tears in the upholstery.
  • Page 24: Contact Information

    ® akworks 923 East Wellspring Road New Freedom, PA 17349 Toll Free (USA only): 800-916-4613 Phone: 717-235-6807 FAX: 717-235-6798 www.oakworks.com ASSEMBLED BY HAND IN THE Manual Part Number MMMNST0020 Revision date: 09.20.12 Edition 1 May, 2010 Printed in English Printed in USA...

Table of Contents