Replacement Parts
Item Description
60mm/2.4" SteadyFlex ESD-Safe Flex Arm & Nozzle Assembly
Replacement ESD-Safe Nozzle/Endpiece
Replacement Wireless Remote Control
Replacement Inlet Cap
Replacement Casters, set of 4 (2 locking, 2 standard casters)
Replacement Fuses (120VAC) Pkg/5
Replacement Fuses (230VAC) Pkg/5

Troubleshooting

Symptom
System turns on but
shuts off immediately.
System will not turn on.
Reduced Airflow
If the unit does not work after checking the above, please contact PACE or, if you are located outside of the
U.S., your Authorized PACE Distributor.
©2018 PACE Inc., Vass, North Carolina. All Rights Reserved
TM
SteadyFlex
ESD-Safe Flex Arm & Nozzle Assembly
Possible Causes
Filter blocked.
Duct work blocked or restricted.
No power supplied to unit
Filter blocked.
Arm attachment not installed
correctly.
Part Number
8886-0850-P1
8884-0154-P1
8884-0153-P1
8884-0152-P1
8884-0151-P1
8884-9962-P5
8884-9963-P5
Solution
Check & change filter(s)
Check that the arms/hoses are not
pinched or bent to sharply.
Make sure the power cord is fully seated
and that the power is turned on.
Check & change filter(s)
Make sure all accessories are fully
seated.