Pace ARM-EVAC 150 Operation Manual

Fume extraction system

Advertisement

Quick Links

Operation Manual for
ARM-EVAC
150 Fume Extraction System
®
Model
ARM-EVAC 150
ARM-EVAC 150
MANUAL P/N 5050-0593
REV. 11 Nov 2018
This manual applies to:
Required Power
120 VAC
230 VAC
Part Number
8889-0150-P1
8889-0155-P1

Advertisement

Table of Contents
loading

Summary of Contents for Pace ARM-EVAC 150

  • Page 1 Operation Manual for ARM-EVAC 150 Fume Extraction System ® MANUAL P/N 5050-0593 REV. 11 Nov 2018 This manual applies to: Model Required Power Part Number ARM-EVAC 150 120 VAC 8889-0150-P1 ARM-EVAC 150 230 VAC 8889-0155-P1...
  • Page 3: Table Of Contents

    Safety ............................1 Introduction ..........................1 Specifications .......................... 2 Environmental Specifications ....................2 Features of Arm-Evac 150 Fume Extraction System ............... 3 Set up ............................4 Front Control Panel & Remote Button Functions ..............6 Maintenance ..........................6 Filter Replacement & Spare Parts ................... 7 Troubleshooting ........................
  • Page 4: Safety

    To insure continued effective performance, the following guidelines must be followed: Dangers 1. PACE Fume Extractors are not intended as replacement of devices designed for removal of poorly adsorbed substances like carbon monoxide, methane, hydrogen, acetylene and other gases. Risk of serious injury or death, fire or explosion may result from improper use.
  • Page 5: Specifications

    Optimal flow rates for use with our flexible arms & accessories The Arm-Evac 150 comes standard with a General Purpose Combo Filter with a 3-stage filtration process consisting of a Pre-Filter for course particle removal, a HEPA-Type Particulate Filter and Gas Filter in a cartridge for efficient filtration.
  • Page 6: Features Of Arm-Evac 150 Fume Extraction System

    Handles (1 on each side) Control Panel Exhaust Vents (1 on each side) Air Inlet (2) Power Switch/Power Receptacle/Fuse Tray Inlet Cap Arm-Evac 150 Fume Extraction System comes complete as shown above www.paceworldwide.com Page 3 ©2018 PACE Inc., Vass, North Carolina. All Rights Reserved...
  • Page 7: Set Up

    Set up 1. The Arm-Evac 150 has been designed for ease of use and maximum installation flexibility in mind. The major considerations for placement of the unit are: Exhaust Vents: Located on both sides of the unit (see image on left). When positioning the unit, make sure airflow to exhaust vents are not blocked/restricted.
  • Page 8 Operation Arm-Evac 150 Front Control Panel Remote Control www.paceworldwide.com Page 5 ©2018 PACE Inc., Vass, North Carolina. All Rights Reserved...
  • Page 9: Front Control Panel & Remote Button Functions

    Each Arm-Evac is supplied with one replacement fuse, also located in the sliding tray. Motor: The Arm-Evac 150 is fitted with a brushless, single inlet motor pump assembly, which does not require routine maintenance. It is important that fume extractor filters are changed on a regular basis to protect the fan assembly.
  • Page 10: Filter Replacement & Spare Parts

    Do not attempt to clean any PACE fume extraction filters for reuse. Cleaning the filters can severely damage the filter media, ruining the filter’s performance. This will result in unfiltered, contaminated air being returned to the working environment.
  • Page 11 Replacement Filter Chart Product Image Name/Part Number Description & Recommended Application Comes standard with the Arm-Evac 150. The Pre-Filter is a lower Pre-Filter efficiency (90% arrestance, EU 4) particle filter that is used to P/N 8883-0112-P5 protect the primary filter from large particles, extending the life of the primary filter.
  • Page 12: Troubleshooting

    Arm attachment not installed Make sure all accessories are fully correctly. seated. If the unit does not work after checking the above, please contact PACE or, if you are located outside of the U.S., your Authorized PACE Distributor. www.paceworldwide.com Page 9...
  • Page 13: Warranty

    Warranty PACE warrants that this equipment will be free of defects in materials and workmanship for a period of one (1) year from the date of receipt by the first user. This warranty does not cover repair of replacement required as a result of misuse, mishandling or improper storage.