After you have removed the ancillary flange, you can insert the grinding disk in the body from
below. See that the ancillary flange and the disk abut against each other precisely. (Fig. 6).
Do not tighten the screws too much to avoid damaging to the disk. The grinding disk on the hub
torque is 7 Nm; you can adjust it using a torque spanner. Now, the grinding disk additional guard
should be fitted on (Fig. 7).
Check the correct bottoming of the disk: it should not move across and lengthwise. With the
grinding disk properly installed, a trial may be performed.
If the grinding disk is vibrating or shows otherwise wobbling, switch off and unplug the machine
before you attempt in clearing the fault.
The machine has a zero voltage circuit breaker, which is disabled on outage and will prevent any
restarting of the machine after the power supply is restored.
Using the sharpening stone and a clamping plate, it is possible to sharpen the disk to obtain the
required profile.