LG Multi V Series Engineering Manual page 127

Ducted indoor unit
Hide thumbs Also See for Multi V Series:
Table of Contents

Advertisement

Table 88: Ducted Low Static (L1, L2, L3 Frames) Indoor Unit General Data.
Model No.
Cooling Mode Performance
Capacity (Btu/h)
Max Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Heating Mode Performance
Capacity (Btu/h)
Max Power Input
(W)
1
L/M/H Power Input at Factory Default (W)
Entering Mixed Air
Cooling Max. (°F WB)
2
Heating Min. (°F DB)
2
Unit Data
Refrigerant Type
3
Refrigerant Control
Sound Pressure
dB(A) (H/M/L)
4
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cable
(No. x AWG)
5
Fan
Type
Motor
Housing
Motor/Drive
Airflow Rate H/M/L (CFM)
Standard Mode
Airflow Rate H/M/L (CFM)
High Mode (Factory Set)
External Static Pressure (in. wg)
Standard Mode
External Static Pressure (in. wg)
High Mode (Factory Set)
Piping
Liquid Line (in., O.D.)
Vapor Line (in., O.D.)
Condensate Line (in., I.D.)
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry nitrogen charge.
All capacities are net with a combination ratio between 95-105%.
Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice.
Current certified ratings are available at www.ahridirectory.org.
Max. power input is rated at maximum setting value.
1
Low ambient performance with LGRED° heat technology is included in Multi V 5 Air Source Units
2
produced after February 2019.
ARNU073L1G4 ARNU093L1G4 ARNU123L2G4 ARNU153L2G4 ARNU183L2G4 ARNU243L3G4
7,500
40
24 / 28 / 31
8,500
40
24 / 28 / 31
76
59
R410A
EEV
27 / 26 / 23
38.6
47.4
2 x 18
Sirocco
1
2
270 / 230 / 200
320 / 250 / 200
270 / 230 / 200
320 / 250 / 200
0
0.1
1/4 Flare
1/2 Flare
1
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
DUCTED LOW STATIC
9,600
12,300
40
85
24 / 29 / 39
29 / 34 / 41
10,900
13,600
40
85
24 / 29 / 39
29 / 34 / 41
76
76
59
59
R410A
R410A
EEV
EEV
30 / 26 / 23
31 / 29 / 26
38.6
50.7
47.4
60.6
2 x 18
2 x 18
Sirocco
Sirocco
1
2
2
3
Brushless Digitally Controlled / Direct
360 / 310 / 250
360 / 310 / 250
0
0
0.1
0.1
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
3
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4
All communication cable to be minimum 18 AWG, 2-conductor, twisted, stranded, shielded and must
5
comply with applicable local and national codes. Ensure the communication cable is properly grounded
at the master outdoor unit only.
point.
General Data
L1, L2, L3 Units
15,400
19,100
85
85
34 / 41 / 56
41 / 56 / 71
17,100
21,500
85
85
34 / 41 / 56
41 / 56 / 71
76
76
59
59
R410A
R410A
EEV
EEV
34 / 31 / 29
36 / 34 / 31
50.7
50.7
60.6
60.6
2 x 18
2 x 18
Sirocco
Sirocco
2
2
3
3
450 / 360 / 310
530 / 450 / 360
450 / 360 / 310
530 / 450 / 360
0
0
0.1
0.1
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
Do not ground the ODU-IDU communication cable at any other
LOW STATIC | 127
24,000
115
48 / 63 / 103
27,300
115
48 / 63 / 103
76
59
R410A
EEV
39 / 35 / 32
59.5
68.3
2 x 18
Sirocco
2
4
710 / 570 / 430
710 / 570 / 430
0
0.1
3/8 Flare
5/8 Flare
1