ABOUT THIS MANUAL Purpose This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference. Scope This manual provides safety and installation guidelines as well as information on tools and wiring. SAFETY INSTRUCTIONS WARNING: This chapter contains important safety and operating instructions.
Operation 1. Only after wire connection is complete and put cover back to the inverter, it’s ok to do commissioning. Otherwise, it will cause electric shock 2. If sunlight is sufficient but little water is pumped, maybe the wires on motor connection are reversely connected.
INTRODUCTION Interest in renewable energy has increased over the past few years due to solar power becoming more cost effective and eco-friendly. This is a solar inverter which allows power to be switched from the DC power obtained from solar panels to the AC power needed to control the pump. With the renewable solar inverter, pumps can adapt to solar power sources rather than traditional electrical supplies or generators.
Product Overview 1. PV input 2. Single-phase AC input 3. AC output 4. RS-485 communication port 5. RS-232 communication port 6. Signal control slot 7. Display screen (Refer to Operation and Display Panel for the details) 8. LED indicators (Refer to Operation and Display Panel for the details) 9.
INSTALLATION Unpacking and Inspection Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package: The unit x 1 User manual x 1 RJ45 cable x 1 ...
Install the unit by screwing four screws. It’s Drill four holes in the marked locations with four recommended to use M5 screws. screws. PV Connection CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
Below are popular solar panel specifications in the market: A. 75-A: 75W, Vmp=17.46V, Imp=4.3A, Voc=21.96V B. 75-B: 75W, Vmp=13.3V, Imp=5.64A, Voc=16.94V C. 140-A: 140W, Vmp=17.9V, Imp=7.82A, Voc=22.0V D. 250-A: 250W, Vmp=30.64, Imp=8.16A, Voc=37.38V Output type PV Panel 75-A PV Panel 75-B PV Panel 140-A PV Panel 250-A 19 pieces in Series...
Suggested cable requirement: Model Typical Wire size Terminal Torque Value Amperage Dimensions d (mm) D (mm) 2.2KW LS 11 AWG 1.3 ~ 1.4 Nm Please follow below steps to implement AC input connection: 1. Before making AC input connection, be sure to disconnect all circuit breakers or disconnectors first. 2.
Single-phase motor connection If applying for single-phase output application, please connect AC output U and W terminals to single-phase motor as shown below: Three-phase motor connection NOTE: If sunlight or AC input is normal, but little water is pumped, maybe the output wires on motor connection are reversely connected.
Remote Communication Connection WARNING: Please do NOT mis-connect the wires between RJ45 and RS485/RS-232 converter. First, please use one RS485 to RS 232 converter as media converter between inverter and computer. Please follow below chart for wiring connection between RS485 on the inverter and media converter. It’s necessary to connect to the utility as power source for the media converter.
Signal Port Status Signal Remote Float Switch (1) Remote Float Switch Water level status Normal Level Open Open Close Low Level Close Open Open High Level Open Close Remote float switch (1): It’s to prevent water tank overflow or underflow by sensing a remote float switch in water tank. When water level is normal, it will keep DI1 &...
OPERATION Power ON/OFF Once the unit has been properly installed, simply press “RUN” button (located on the button area) to turn on the unit. Operation and Display Panel The operation and display panel, shown in below chart, is on the top case of the inverter. It includes four indicators, six function buttons and a display screen, indicating the operating status and input/output power information.
Function Buttons Function Button Description ESC/PROG To enter or exit setting mode. ENTER To confirm the selection/value in setting mode. To turn on the unit, press this button for at least 1 second. To turn off the unit, press this button for at least 1 second. ...
Page 16
Parameter setting procedure for water pump Operation steps Screen Display 1. Press “ESC/PROG” button for 500ms. Then, it will display “P0” in display screen. 2. Press “ENTER” button for 500ms, display screen will show as in the right chart. 3. Press “ENTER” button again to start to set up rated power of the water pump.
Page 17
7. Press “ENTER” button to be able to set up nominal voltage of the water pump. Press “ENTER” and “DOWN” buttons at the same time to switch cursor. Then, press “UP” or “DOWN” button to change value for nominal voltage. Until it shows correct nominal voltage, please press “ENTER”...
Page 18
Parameter Setting Table 〇: This parameter can be modified no matter the inverter is in operation or off status. ◎: This parameter can be modified only when inverter is turned off and it shows 0.00 Hz in display screen. Program # Description Setting Range Unit...
Page 19
Program # Description Setting Range Unit Default Value Note P3 Protection setting for the inverter of the water pump Sleep mode while PV P3.00 10-3600 〇 energy is weak Sleep mode P3.01 10-7200 1200 〇 running Allow pumping P3.02 1-3600 〇...
Fault and Warning Code All fault and warning codes can be reset by pressing “RST” button except for A07 and A11. When faults or warning occur, press “RST” button and the inverter will enter standby mode. Please press “RUN” button to turn on the inverter for operation again.
Warning Reference Codes Warning code Warning type Possible Cause PV input voltage is too low. 1. PV input voltage is too low. 2. Sunlight is too weak. Weak sunlight Sunlight is too weak Dry running Water level in the well is low. Nominal power of motor is not setting.
SPECIFICATIONS MODEL 2.2KW LS Rated Output Power 2200 W Power grid or AC generator input 220/230/240V(1PH) Nominal voltage (-15%~+10%) Frequency range 47-63Hz PV INPUT (DC) Nominal DC Voltage / Maximum 330 VDC / 450 VDC DC Voltage Start-up Voltage 120VDC MPPT Voltage Range 120 VDC ~ 420VDC Number of MPP Trackers...