10.8 How to Rx Calibration

1. Setting And Test same as Rx Standalone Test
2. Read the Gain Value on the HWTest Software
3. Using the calculation Excel File, Calculate Rx Gain Table Value
4. Using Caledit Software, Open the Basic.bin
5. Write the Calculated Value on the Rx Gain Table of Basic.bin

10.9 How to Tx Calibration

1. Setting And Test same as Tx Standalone Test (Start From the Max Level of Each Band)
2. Checking 'Scaling Factor' instead of 'Power Level' (Don't Change the Power Ramp Table!)
3. Change the 'Scaling Factor' Value for MS to transmit the Proper Value
(Check the Power Level Table on Next Page)
4. Write the 'Scaling Factor' Value on Ramp Factor Table of Basic.bin
5. Change the Tx Level of the Test Equipment and do the same procedure from 1~4

10.10 Target powers in dBm for each power level

Power Level
0
1
2
3
4
5
6
7
8
9
GSM
DCS
Power Level
29
28
26
24
22
32
20
31
18
29
16
27
14
25
12
- 121 -
10. STAN ALONE TEST
GSM
10
23
11
21
12
19
13
17
14
15
15
13
16
11
17
9
18
7
19
6
DCS
10
8
6
5
4
3