Discharge Piping; Installation Outdoors; 5.0 Start Up Procedure - Neptune 7000 Series Installation Operation & Maintenance

Mechanical ''dia-pump''
Hide thumbs Also See for 7000 Series:
Table of Contents

Advertisement

3.0

DISCHARGE PIPING

3.0.1 It is recommended that the Mechanically Actuated Diaphragm metering pump operate against a suitable
back pressure to facilitate better operation of the check valves.
3.0.2 To protect the pump, it is recommended that an external relief valve as manufactured by Neptune Chemical
Pump Company, or equal, be placed in the discharge line of the pump to avoid over pressure.
3.0.3 Discharge piping should at least equal to discharge port size of the pump's Liquid Head.
NOTE: All pipes and valves must have a working pressure at least twice the system maximum pressure.
CAUTION:
Do not attempt to run the pump in excess of its nameplate rating.
4.0

INSTALLATION OUTDOORS

The Mechanically Actuated Diaphragm metering pump is a totally enclosed pump, which can be used outdoors or
indoors. When installed outdoors, make sure that the pump is protected against extremes of nature as follows:
4.0.1
Running of the pump when exposed to tropical sunshine with ambient temperature above 100°F (37.8°C)
would cause excessive motor temperatures. The pump should be shaded and located in such a way as to
permit an ample degree of air circulation.

5.0 START UP PROCEDURE

The following start up procedure is complete and does repeat instructions on filling the gearbox and pump.
5.0.1
Open suction and discharge valves. (See recommendation 1.0.5)
5.0.2
Set capacity control knob to indicate zero by turning clockwise.
5.0.3 Adjust backpressure close to zero.
5.0.4
Start pump.
5.0.5
On initial start-ups: Check for proper motor rotation (Refer to Paragraph 1.0.6). Listen for any abnormal
motor or crank noises, and if present, refer to trouble shooting chart (page 21)
5.0.6
Adjust pump to required capacity by turning hand knob counterclockwise.
5.0.7
Adjust system pressure to requirement.