8.6
Liquid-cooled Active Line Modules for the grid infeed, chassis format
8.6.1
Description
The self-commutating infeed / regenerative feedback units act as step-up converters and
generate a stabilized DC link voltage that is 1.5x greater (factory setting) than the rated line
supply voltage. In this way, the connected Motor Modules are isolated from the line voltage.
This improves the dynamic response and control quality because line tolerances and
fluctuations do not affect the motor voltage.
If required, the Active Line Modules can also provide reactive power compensation.
Table 8- 14
Grid infeed
System Manual, 04/2015, A5E03347436A
8.6 Liquid-cooled Active Line Modules for the grid infeed, chassis format
Active Line Modules for grid infeed
Frame size HXL
Device overview
Frame size JXL
167