Preset Cone-Fire Programs - Sentry Xpress 5.0 Instructions For Use Manual

Digital temperature controller cone-fire and ramp-hold
Table of Contents

Advertisement

Sentry Xpress 5 Cone-Fire / Ramp-Hold
Preset Cone-Fire Programs - °F
These are the firing schedules programmed in Cone-Fire mode. To customize a schedule, write down your
changes. Then load your new schedule into Ramp-Hold.
Low Fire Cones °F
Segment 1
Cone
Rate 1 Temp. 1
022
396
979
021
396
1004
020
396
1051
019
396
1144
018
396
1211
017
396
1252
016
396
1314
015
396
1348
014
396
1377
013
396
1431
012
396
1474
011
396
1499
Medium Fire Cones °F
Segment 1
Cone
Rate 1 Temp. 1
010
324
1022
09
324
1022
08
324
1022
07
324
1022
06
324
1022
05
324
1022
04
324
1022
03
324
1022
02
324
1022
01
324
1022
High Fire Cones °F
Segment 1
Cone
Rate 1 Temp. 1
1
324
1022
2
324
1022
3
324
1022
4
324
1022
5
324
1022
6
324
1022
7
324
1022
8
324
1022
9
324
1022
10
324
1022
30
Segment 2
Rate 2 Temp. 2
108
1087
108
1112
108
1159
108
1252
108
1319
108
1360
108
1422
108
1456
108
1485
108
1539
108
1582
108
1607
Segment 2
Rate 2 Temp. 2
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
Segment 2
Rate 2 Temp. 2
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
153
1112
Do not leave your kiln unattended during operation.
Segment 3
Rate 3 Temp. 3
180
1549
180
1580
180
1620
180
1681
180
1720
180
1780
180
1837
180
1879
180
1908
180
1938
Segment 3
Rate 3 Temp. 3
162
1863
162
1872
162
1890
162
1908
162
1951
162
2016
162
2046
162
2064
162
2084
162
2129
Segment 4
Rate 4 Temp. 4
108
1657
108
1688
108
1728
108
1789
108
1828
108
1888
108
1945
108
1987
108
2016
108
2046
Segment 4
Rate 4 Temp. 4
108
2079
108
2088
108
2106
108
2124
108
2167
108
2232
108
2262
108
2280
108
2300
108
2345