■ If any failure occurs, check the following before contacting a service or a dealer.
■ If the check lamp comes "ON" and the failure code is displayed, take proper actions and then restart the unit.
(Re-plug in the unit or turn the unit "ON" few minutes after the check lamp has come "ON")
■ If such procedure does not work, contact the nearest service center.
■ Certain non hazardous failures will shut down the unit, but will not illuminate check light. Press ON/OFF button
to obtain error code.
Symptoms
▶
No indication on the
water temperature
indicator
▶
Temperature is indicated
but the unit does not
work
▶
"02" is indicated on the
The unit does
temperature indicator
not work
▶
"01" is indicated on the
temperature indicator
▶
When the unit is started, the ignition
fails and the check lamp comes "ON"
▶
Ignition fails and the exhaust fan runs
continuously
▶
The unit runs properly but heat
performance is poor
▶
The unit runs normally but hot water is
not supplied
▶
Pressure falls
▶
Loud noise during the ignition and
combustion
▶
Hot water supply stops
QVM 9
Series
Troubleshooting
CAUTION
Causes
▶
Blown fuse
▶
Power failure
▶
Room temperature is higher than the set
temperature
▶
Set temperature at the unit
thermostat is low
▶
No water in the heating pipe
▶
Water filling valve failure
▶
No tap water supply
▶
Clogged heating pipe
▶
Circulation pump failure
▶
Low or no gas pressure
▶
No flame detection
▶
Intermediate valve closed
▶
No ignition
▶
Air pressure switch tube disconnected
▶
Incorrect installation of flue
▶
Clogged flue exhaust pipe
▶
Closed valve on the heating line or
clogged pipe(Heating water)
▶
Air in the heating pipe
▶
Circulation pump does not work
▶
Leak in heating pipe
▶
Low water pressure
▶
Circulation pump does not work
▶
Defective 3-way valve
▶
Leakage in piping
▶
Installation of flue duct
▶
Clogged flue pipe(s)
▶
Clogged hot water line
▶
Defective hot water flow switch
38
Troubleshooting
▶
Replace new fuse
▶
Wait until the power is restored
▶
Check circuit breakers
▶
Increase the set temperature at the
room thermostat
▶
Increase the set temperature at the
thermostat
▶
Fill the heating water
▶
Contact the service center
▶
Check for any clogging in the heating
pipe. If the pipe is clogged, contact the
unit installer
▶
Clean the heating strainer
▶
Check the circulation pump
※ After removing the cause, press the
"HEAT ON" button again
▶
Contact for service
▶
Contact for service
▶
Open the valve
▶
Contact for service
▶
Connect the tube
▶
Correct the wrong installation
▶
Check the smoke stack
▶
Check the heating pipe(strainer)
▶
Purge the air from the piping
▶
Contact for service
▶
Fix the leak
▶
Install a pressurizing pump
▶
Contact for service
▶
Contact for service
▶
Contact for service
▶
Contact for service
▶
Contact for service
▶
Clean the strainer at the inlet of the hot
water flow switch
▶
Contact for service